FC-301P4K0T4131X7310 Danfoss
Wake Industrial LLC is not an authorized distributor of this product.
The Danfoss FC-301P4K0T4131X7310 is part of the VLT FC 301 Automation Drives series and operates with three-phase power at a mains voltage of 380 to 480 VAC. It delivers a rated power of 4.0 kW at 400 V and 5.0 hp at 460 V, with a maximum output frequency of 590 Hz. This drive features an analog output resolution of 12 bits and achieves an efficiency of 0.97 at rated current.
Internal Product Review
The FC-301P4K0T4131X7310 is a Danfoss VLT FC 301 automation drive with three-phase 380 to 480 VAC input and a 4.0 kW rating at 400 V. A 0.97 efficiency at rated current and a 590 Hz maximum output frequency make the drive an excellent choice for precise, energy-conscious control.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
The FC-301P4K0T4131X7310 is a variable frequency drive manufactured by Danfoss for the VLT FC 301 Automation Drives series. It conditions incoming power and delivers a regulated, adjustable output so automation controllers can vary induction motor speed and torque in conveyors, pumps, and general process machinery. Acting as the power interface within the control chain, the drive translates low-level commands into the motor voltage and frequency required for synchronized industrial motion.
The drive operates on a three-phase mains supply of 380–480 VAC and belongs to the VLT AutomationDrive FC product group, carrying the internal series identifier 301. At 400 V, it can deliver 4.0 kW while drawing 9.0 A of input current and supplying 10 A at the motor terminals. Conversion efficiency reaches 0.97, which helps limit internal heat buildup during normal operation. Output frequency extends to 590 Hz, supporting oversynchronous motor operation when the connected motor and application permit it. A 12-bit analog output reports process data, while a 40 mA digital source channel provides status signaling. The logic inputs accept up to 28 V DC for direct connection to compatible PLC outputs.
The thermal design accommodates a full-load dissipation of 124 W, and apparent power reaches 6.9 kVA for upstream protective device sizing and supply planning. For flux-mode control, the inverter sustains 300 Hz of fundamental frequency, while its carrier can reach 32 kHz to reduce motor acoustic noise at suitable operating points. Motor leads may span 50 m when shielded or 75 m when unshielded without exceeding the stated electromagnetic compatibility limits. An internal relay switches 240 V AC at 2 A for alarms or basic status signaling, and a 5.0 hp rating at 460 V supports the corresponding motor load.