The Danfoss FC-301P37KT2131B8981 is part of the VLT FC 301 Automation Drives series and offers a power rating of 37 kW with an efficiency of 0.97. It operates on three phase power at 200 - 240 VAC and has a horsepower of 50 HP. The drive offers a maximum cable cross-section of 95 mm² and provides a 24 V output with a maximum load of 200 mA.

Warranty
Wake Industrial Warranty

Quote Request Form:

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The FC-301P37KT2131B8981 is an adjustable-speed drive produced by Danfoss as part of the VLT FC 301 Automation Drives series. The unit rectifies the incoming AC supply and converts it into a controlled DC bus. It then inverts the DC power to supply three-phase motors with adjustable frequency and voltage, allowing industrial process equipment to match motor speed to real-time load demands. This regulation supports applications such as conveyors, pumps, fans, and production machinery that require controlled acceleration and consistent speed.

The drive accepts a three-phase input of 200–240 VAC and delivers up to 37 kW of mechanical output, which corresponds to 50 HP. With a 230 V supply, the apparent input demand is 57 kVA, which assists with the selection of upstream transformers and protection devices. Electrical conversion efficiency reaches 0.97, helping limit heat generation inside control cabinets. A high-voltage warning occurs at 405 V DC, while an overvoltage alarm activates at 410 V DC. Both thresholds are above the 390 V DC brake-chopper activation level, allowing regenerative energy to be diverted before a fault shutdown occurs. The control terminals supply 10 V at 15 mA for analog potentiometers and 24 V at 200 mA for sensors, while the digital inputs tolerate levels up to 28 V DC. Logic outputs can sink 40 mA, and each STO channel draws 50 mA rms for safety-relay load calculations.

The modulation stage can generate carrier frequencies up to 32 kHz, and its pulse train for encoder interfaces reaches 110 kHz, supporting precise torque control on high-speed machinery. Motor leads may extend up to 50 m when shielded or 75 m when unshielded. These cable limits help prevent excessive capacitive loading at the inverter output. The power terminals accept copper conductors with a maximum cross-sectional area of 95 mm², providing capacity for the rated motor current. A mains phase monitor prevents the drive from starting when an input phase is missing. This protection reduces the risk of operating the rectifier stage with an unbalanced supply and helps protect the connected motor system.

10 V Output Max Load
15 mA
24 V Output Max Load
200 mA
Apparent Power (@230 V)
57 kVA
Brake Active Voltage
390 V DC
Digital Input Max Voltage
28 V DC
Digital Output Current
40 mA
Efficiency
0.97
High-voltage Warning
405 V DC
Horse Power
50 HP
Mains Voltage
200 - 240 VAC
Max Cable Cross-section
95 mm²
Max Frequency Output
32 kHz
Max Pulse Frequency
110 kHz
Max Shielded Motor Cable
50 m
Max Unshielded Motor Cable
75 m
Overvoltage Alarm
410 V DC
Power Phase
Three Phase Power
Power Rating
37 KW
Product Group
VLT AutomationDrive FC
Series Identifier
301
Sto Input Current
50 mA rms

Frequently Asked Questions about FC-301P37KT2131B8981:

Q: What is the power rating for the Danfoss FC-301P37KT2131B8981 drive?

A: The FC-301P37KT2131B8981 Automation Drive operates at a power rating of 37 kW.

Q: What mains voltage range is compatible with the FC-301P37KT2131B8981?

A: This model supports a mains voltage range from 200 to 240 VAC.

Q: What is the maximum frequency output of the FC-301P37KT2131B8981?

A: The maximum output frequency of the drive is 32 kHz, allowing for variable motor speed control.

Q: What is the efficiency rating of the Danfoss FC-301P37KT2131B8981 drive?

A: The FC-301P37KT2131B8981 has an efficiency rating of 0.97, assisting in energy-conserving operation.

Q: What is the maximum voltage for digital inputs on the FC-301P37KT2131B8981?

A: This drive provides a maximum digital input voltage of 28 V DC for input signal compatibility.


Internal Product Review

  • ‘‘The FC-301P37KT2131B8981 is a Danfoss VLT FC 301 automation drive rated at 37 kW for 200-240 VAC systems. High 0.97 efficiency and a 32 kHz maximum output frequency support smooth motor control and strong energy performance. An excellent choice for demanding drive applications, especially where 50 HP capacity is required.’’