FC-301P30KT2131B6072 Danfoss
Wake Industrial LLC is not an authorized distributor of this product.
No Tariffs On US Orders- Straightforward Pricing: No Rush Fees, No Credit Card Fees
The Danfoss FC-301P30KT2131B6072 is part of the VLT FC 301 Automation Drives series and is rated for 40 horsepower and 30 kilowatts of power using three phase input at 200 to 240 volts AC. It features a 12-bit analog output resolution, max output frequency of 590 Hz, and supports both shielded and unshielded motor cables up to 50 and 75 meters, respectively.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
The FC-301P30KT2131B6072 AC variable frequency drive is produced by Danfoss for the VLT FC 301 Automation Drives series. The unit modulates three-phase mains power to control induction motor speed and torque in conveyors, pumps, and general process machinery. By adjusting frequency and voltage in real time, it allows plant controllers to match motor output to load requirements while maintaining energy efficiency during continuous industrial operation.
The inverter accepts a 200–240 VAC three-phase power supply and delivers up to 30 kW, which corresponds to 40 HP of continuous mechanical power. Its internal series identifier is 301, aligning its parameter structure with other drives on the platform. Carrier switching can reach 32 kHz, while the commanded motor frequency can reach 590 Hz. A separate 300 Hz flux ceiling limits field-oriented control calibration. The drive allows one power-up per minute, and line symmetry must remain within a 3.0% phase imbalance. The input section has a true power factor of at least 0.9 and provides displacement correction through internal capacitors. Relay outputs rated at 240 V AC and 2 A provide connections for contactors. The Safe Torque Off circuitry monitors a 50 mA RMS channel for emergency shutdown commands.
The analog feedback output provides 12-bit resolution, allowing the connected controller to receive detailed signal values across the available output range. Logic terminals accept command levels up to 28 V DC, while status outputs can source a maximum current of 40 mA. Shielded motor cables may extend up to 50 m before cable length begins to affect voltage quality or electrical noise. Unshielded motor cables may extend up to 75 m under suitable installation conditions. Internal harmonic compensation maintains a displacement factor of >0.98 during operation. These control connections support external commands, operating feedback, relay signaling, and safety-related shutdown functions without requiring separate signal conversion hardware.