FC-301P2K2T4131X7308 Danfoss
Wake Industrial LLC is not an authorized distributor of this product.
The Danfoss FC-301P2K2T4131X7308 is part of the VLT FC 301 Automation Drives series and has a power rating of 2.2 kW with a supply voltage range of 380 to 480 VAC. This three-phase drive offers a maximum output frequency of 590 Hz and an input current of 5.0 A at 380 to 440 V. It provides an efficiency of 0.97 and supports a maximum power cable cross-section of 4 mm² (12 AWG).
Internal Product Review
The FC-301P2K2T4131X7308 is a Danfoss VLT FC 301 automation drive with a 2.2 kW rating and three-phase power input. Performance looks efficient and electrically stable, supported by 0.97 efficiency and a true power factor of at least 0.9. Output capability up to 590 Hz stands out as a key advantage for precise motor control.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
The FC-301P2K2T4131X7308 variable frequency drive is manufactured by Danfoss as part of the VLT FC 301 Automation Drives series. The device converts constant three-phase mains power into a regulated output waveform for controlling an induction motor. In typical automation lines, the drive is installed between the power supply and the motor, allowing a PLC to vary shaft speed and dynamic torque without mechanical throttling. This control can improve energy use and extend component life in pumps, conveyors, and material-handling systems.
The inverter operates on three-phase 380–480 VAC networks with voltage fluctuations of up to ±10%. It draws 5.0 A at 380–440 V during rated service, and its power module delivers 2.2 kW to the motor terminals. Output frequency is adjustable from 0–590 Hz, while a dedicated flux mode covers 0–300 Hz for magnetizing control at very low speeds. The synthesized output voltage spans from 0% to 100% of the incoming line voltage. The control system also enforces a maximum phase imbalance of 3% to protect the DC bus. Across the modulation range, the thermal design limits conversion losses and provides an efficiency of 0.97. The supply frequency can be either 50 Hz or 60 Hz with a tolerance of ±5%, allowing operation with common industrial power systems.
The internal brake chopper engages the DC link at 728 V DC, dissipating excess energy during rapid deceleration. Heat dissipation is limited to 88 W under nominal operating conditions. A measured true power factor of ≥0.9 reduces the reactive current drawn from the power grid. Shielded motor leads may run up to 50 m, while unshielded leads may extend to 75 m. The terminal block accepts conductors up to 4 mm², which corresponds to 12 AWG wiring. These cable limits help maintain electromagnetic compatibility and support stable control during rapid flux transitions.