FC-301P2K2T4131B0966
Wake Industrial LLC is not an authorized distributor of this product.
No Tariffs On US Orders- Straightforward Pricing: No Rush Fees, No Credit Card Fees
The FC-301P2K2T4131B0966 Frequency Converter delivers a shaft output of 2.2 kW (3.0 hp), has a continuous output current of 5.6A at 3x380–440V, and an enclosure protection rating of IP20. Part of the VLT AutomationDrive FC 301 series by Danfoss, it boasts an efficiency of 97% and an intermittent overload output current capability of 9A.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
In terms of versatility and performance, Danfoss’ FC-301P2K2T4131B0966 is next to none. With a durable IP 20 chassis and an integrated EMC filter, this frequency converter exhibits high accuracy, efficiency, and tolerance. To deliver full-scale performance, the frequency converter’s input terminals must be connected to an AC line voltage of 380 to 480 volts. A maximum voltage deviation of plus or minus 10% is acceptable. Beyond the tolerance range, however, the frequency converter’s performance will decrease. The output performance of the converter is directly proportional to the amount of decrease in the supply voltage. For instance, a 15% decrease in the supply voltage will lead to a 15% decrease in the converter’s output performance.
At the nominal voltage supply range, the FC-301P2K2T4131B0966 delivers an expected shaft output of 2.2 kilowatts or 3 horsepower. For this converter, the default chassis is the A2 enclosure with a protection rating of IP 20. The recommended cable cross-section for the default chassis is 3 x 4 sq. mm. At rated load conditions, the FC-301P2K2T4131B0966 achieves a nominal efficiency of 96% and a total power loss of 116 watts. With the standard voltage supply range, the converter can draw a maximum continuous input current of 5 amperes. Especially during starting conditions, the FC-301P2K2T4131B0966 can safely draw an intermittent input current of 8 amperes.
To avoid damaging the electronic components inside the FC-301P2K2T4131B0966, the ambient operating range must not exceed 50 degrees Celsius. For transport or storage purposes, however, the maximum ambient temperature may safely reach up to 65 degrees Celsius. For subfreezing environments, the FC-301P2K2T4131B0966 can withstand a minimum temperature of -10 degrees Celsius with reduced performance. To acquire this versatile frequency converter with a one-year warranty, order now at Wake Industrial.
Frequently Asked Questions about FC-301P2K2T4131B0966:
Q: What is the maximum THD that the FC-301P2K2T4131B0966 can tolerate?
A: The FC-301P2K2T4131B0966 can tolerate a maximum THD of 10% during normal operation.
Q: What should be the relative humidity during the operation of the FC-301P2K2T4131B0966?
A: During operation, the relative humidity must be non-condensing, and it must not exceed the range of 3 to 95%.
Q: What is the maximum voltage input for the FC-301P2K2T4131B0966’s digital terminal?
A: For each digital input terminal of the FC-301P2K2T4131B0966, the maximum voltage is 28 VDC.
Q: What is the voltage level for the FC-301P2K2T4131B0966’s STO terminal?
A: For the FC-301P2K2T4131B0966’s STO terminal, the voltage level must be between 0 and 24VDC.
Q: What is the voltage range for the FC-301P2K2T4131B0966’s analog input terminals?
A: Each analog input terminal of the FC-301P2K2T4131B0966 has a scalable voltage range of -10 to 10 V.