FC-301P2K2T2134L2179 Danfoss
Wake Industrial LLC is not an authorized distributor of this product.
The Danfoss FC-301P2K2T2134L2179 is a three-phase automation drive from the VLT FC 301 Automation Drives series with a power rating of 2.2 kW or 3.0 HP. It operates on a mains voltage of 200 to 240 VAC with a supply frequency of 50 or 60 Hz and supports a continuous output current of 10.6 amps. The drive offers an efficiency of 0.96 and a displacement power factor greater than 0.98.
Internal Product Review
The FC-301P2K2T2134L2179 is a Danfoss VLT FC 301 automation drive built for three-phase power and 200 to 240 VAC service. Technical performance is impressive, with 0.96 efficiency at rated current and a displacement power factor above 0.98 that support clean, economical operation. The 10.6 A continuous output current and 0 to 590 Hz output frequency give this drive strong flexibility for precise motor control.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
The FC-301P2K2T2134L2179 is a three-phase AC variable frequency drive manufactured by Danfoss for the VLT FC 301 Automation Drives series. It converts a constant 200 to 240 VAC mains supply into variable-voltage, variable-frequency output power, allowing a PLC to regulate induction motor speed, torque, and energy use. The compact controller is suitable for fan, pump, and conveyor duties in packaging lines, HVAC air handlers, and general material-handling systems. Its housing maintains the same mechanical outline as larger FC 301 models, which supports consistent panel layouts across systems that use multiple drive sizes.
The rated motor output is 2.2 kW, indicating the continuous power available when the drive is paired with a compatible motor. At the output terminals, the inverter delivers 10.6 A of RMS current and provides 4.22 kVA of apparent power at 230 V. Frequency control spans 0 to 300 Hz in flux mode and reaches 0 to 590 Hz in standard mode, supporting oversynchronous operation for high-speed applications. Efficiency reaches 0.96 at rated current, limiting the portion of incoming energy that is dissipated as heat. Output voltage is adjustable from zero to 100 percent of the supply voltage. Stable operation is maintained on 50 or 60 Hz utility networks with frequency deviations of up to ±5 percent.
The input section draws 9.5 A when the drive operates at its rated load, while internal power losses are 116 W. These values can be used to determine the airflow needed within the control cabinet. A displacement power factor above 0.98 minimizes reactive demand, while a true power factor of at least 0.9 helps keep upstream conductors within their thermal limits. Line voltage imbalance must remain below 3 percent to prevent overcurrent alarms. Motor leads can extend to 50 m with shielded cable or 75 m with unshielded cable, reducing the risk of excessive reflected-wave voltage at the motor terminals. The drive tolerates three-phase voltage changes throughout the 200 to 240 VAC input range and uses automatic voltage boost to maintain motor torque.