FC-301P22KT4134L2692 Danfoss
Wake Industrial LLC is not an authorized distributor of this product.
No Tariffs On US Orders- Straightforward Pricing: No Rush Fees, No Credit Card Fees
The Danfoss FC-301P22KT4134L2692 is part of the VLT FC 301 Automation Drives series and has a power rating of 22 kW with a 30 horsepower output. It operates on three phase power with a supply voltage range of 380 to 480 VAC and a frequency of 50 or 60 Hz. The drive supports a maximum output frequency of 590 Hz and has an overload capacity of 160% for one minute within ten minutes.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
The FC-301P22KT4134L2692 variable frequency drive is produced by Danfoss as part of the VLT FC 301 Automation Drives series. This compact, panel-mounted inverter regulates the speed and torque of three-phase induction motors in automated conveyors, mixers, and pump modules by converting incoming AC power into a pulse-width-modulated output. Through integrated control terminals, it accepts hardwired logic signals and scaled analog commands, enabling motor performance to match process demand while limiting mechanical stress and energy consumption.
The drive accepts 380 to 480 VAC from a three-phase power supply and tolerates a mains imbalance of 3.0%. It operates at supply frequencies of 50/60 Hz ±5% and delivers a continuous output of 22 kW, equivalent to 30 HP, for standard-duty loads. When rapid acceleration is required, the power section tolerates a 160% overload for one minute within each ten-minute interval. Carrier modulation allows the motor frequency to reach 590 Hz for high-speed induction applications, while flux-oriented operation is limited to 300 Hz to favor torque density. Connected motors and switchgear must be selected to remain within these electrical and thermal limits.
Protective features address wiring faults and transient events. The built-in brake chopper activates at 778 V DC, diverting surplus energy during regenerative deceleration, and an overvoltage alarm is triggered at 820 V DC before component limits are reached. Logic terminals accept 24 V signals at levels up to 28 V DC, while the transistor output can supply 40 mA for status feedback to PLC inputs. Power conductors with cross-sectional areas up to 35 mm² can be connected to the spring terminals. Motor cable runs may extend up to 50 m with shielded cable or 75 m with unshielded cable while remaining within electromagnetic compatibility guidelines.