FC-301P22KT4131X7286 Danfoss
Wake Industrial LLC is not an authorized distributor of this product.
The Danfoss FC-301P22KT4131X7286 is part of the VLT FC 301 Automation Drives series and has a power rating of 22 kW with a maximum output frequency of 590 Hz. This drive supports three phase power at 380 to 480 VAC and provides 30 horsepower. It features 4 digital inputs, 2 digital outputs, and an efficiency of 0.98 at rated output.
Internal Product Review
The FC-301P22KT4131X7286 is a Danfoss VLT FC 301 automation drive rated for 30 HP on 380 - 480 VAC systems. Technical performance is especially strong, with 0.98 efficiency at rated output and a displacement power factor above 0.98. A 160% overload capacity for 1 min/10 min makes the drive a dependable choice for demanding automation duty.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
The FC-301P22KT4131X7286 is a Danfoss AC variable-frequency drive in the VLT FC 301 Automation Drives series. The unit is intended for equipment that requires electrical speed control rather than mechanical throttling. By converting fixed three-phase mains power into a programmable output waveform, it allows controllers to match motor torque to process demand. This control method can improve energy use and extend the service life of conveyors, pumps, and fan arrays.
Operating on three-phase lines, the drive accepts a mains voltage range of 380–480 VAC and supports continuous motor power up to 22 kW. It maintains a conversion efficiency of 0.98 at rated output, limiting heat generation inside control cabinets. A short-term overload capacity of 160% for one minute every 10 minutes accommodates acceleration surges, while the switching frequency reaches 32 kHz to minimize audible noise. The inverter can raise the fundamental output frequency to 590 Hz, and flux-vector regulation is available up to 300 Hz for precise speed control. Output voltage tracks the supply voltage and can reach 100% of the incoming level.
To interface with automation systems, the FC 301 provides four digital inputs and two digital outputs that can be assigned to start, stop, or speed-reference functions. Motor leads may use shielded cable runs up to 50 m or unshielded runs up to 75 m without derating. At rated load, the unit has a true power factor of at least 0.9 and a displacement factor greater than 0.98, reducing reactive current on the plant bus. The three-digit series identifier 301 distinguishes its control capabilities from those of higher-level FC 302 models. The design permits only one power-up per minute, so start sequencing must account for this interval in applications that use automatic changeover contactors.