FC-301P1K5T4131X7307 Danfoss
Wake Industrial LLC is not an authorized distributor of this product.
The Danfoss FC-301P1K5T4131X7307 is part of the VLT FC 301 Automation Drives series and has a power rating of 1.5 kW with a horse power of 2.0. It supports three phase power and operates on a mains voltage of 380 to 480 VAC with a supply frequency of 50 or 60 Hz. The drive features a maximum output frequency of 590 Hz and includes one relay output rated at 240 V AC, 2 A.
Internal Product Review
The FC-301P1K5T4131X7307 is a Danfoss VLT FC 301 automation drive rated for 1.5 kW with 380 to 480 VAC mains input. Three-phase power and a true power factor of at least 0.9 support efficient integration in demanding drive systems. A maximum output frequency of 590 Hz makes this unit a strong choice for responsive motor control.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
The FC-301P1K5T4131X7307 is a variable-frequency drive manufactured by Danfoss within the VLT FC 301 Automation Drives series. It converts fixed-frequency, three-phase mains power into a modulated output so plant controllers can adjust induction motor speed without using mechanical throttles. The unit supports conveyors, pumps, and mixers that require closed-loop speed or torque regulation in automated production cells. Its adjustable output allows connected machinery to respond to changing process demands while maintaining controlled motor operation.
The input section accepts a mains voltage range of 380–480 VAC, matching common industrial power supplies, and delivers a continuous electrical output of 1.5 kW, or approximately 2.0 HP. Internally, the control algorithm tracks motor magnetizing current up to a maximum flux frequency of 300 Hz, while the inverter stage can reach a synthesized output frequency of 590 Hz for applications that need an extended speed range. The drive has an A-size frame, one programmable relay output rated at 240 VAC and 2 A, and a 24 V auxiliary rail that can supply 200 mA to sensors or small actuators. Power and motor conductors may have a cross-sectional area of up to 4 mm². Cable length is limited to 50 m for shielded cable and 75 m for unshielded cable to preserve switching waveform fidelity.
The thermal model permits an overload of 160% for one minute in every 10 minutes, allowing the drive to accommodate brief current surges during acceleration. The input has a true displacement power factor of at least 0.9, helping limit reactive current on the supply. The rectifier tolerates a maximum line-to-line voltage disparity of 3.0% phase imbalance. Supply lines operating at 50/60 Hz ±5% are accepted without parameter changes, and the DC-link brake activates when the bus voltage reaches 728 V DC to protect the power devices. Cable shields can be bonded effectively to reduce conducted emissions, while the compact enclosure helps conserve installation space inside a control cabinet.