The Danfoss FC-301P1K1T2134L2177 is part of the VLT FC 301 Automation Drives series and supports three phase power with a mains voltage range of 200 to 240 VAC. It is rated for 1.1 kW power and 1.5 horsepower, with a maximum input current of 5.9 A and rated output current of 6.6 A. This drive achieves an efficiency of 0.96 and has a continuous apparent power of 2.63 kVA at 230 V.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
The FC-301P1K1T2134L2177 is an AC variable frequency drive manufactured by Danfoss for the VLT FC 301 Automation Drives series. Designed for cabinet mounting, it converts fixed-frequency three-phase power into a pulse-width-modulated output so that PLCs can adjust motor speed in ventilation, pumping, or material-handling lines. By aligning motor torque with the real-time load, the unit supports energy-efficient operation and can reduce unnecessary mechanical stress on connected equipment.
With a 230 V supply, the inverter can deliver a continuous apparent power of 2.63 kVA, corresponding to a shaft capacity of 1.5 HP or 1.1 kW. Electrical efficiency reaches 0.96, so approximately 4% of the incoming energy is dissipated as heat during rated operation. Power quality is maintained by a displacement power factor greater than 0.98 and a true power factor of at least 0.9, limiting the reactive current drawn from the mains. The control terminal provides a digital sink or source output rated at 40 mA for status signaling, while the analog output provides 12-bit resolution for proportional feedback signals. The motor circuit can continuously supply 6.6 A. The drive also has a fault-clearing capacity of 100 kA RMS symmetrical.
The input accepts three-phase line voltages between 200–240 VAC and tolerates a mains imbalance of up to 3%. Peak current draw is limited to 5.9 A. The drive permits no more than two power-ups per minute, which must be considered when configuring automatic restart sequences. The control electronics are isolated from external power circuits, while command inputs accept no more than 28 V DC and have an impedance of 4 kΩ. Power loss from switching and magnetic components is limited to 63 W. Convection airflow in a properly designed control cabinet removes the generated heat without requiring a separate cooling system.