FC-301P15KT4E20H1XGXXXXSXXX Danfoss
Wake Industrial LLC is not an authorized distributor of this product.
The FC-301P15KT4E20H1XGXXXXSXXX is a 20 HP automation drive from Danfoss, part of the VLT FC 301 Automation Drives series. It operates at 15 kW with a three-phase power input of 380 to 480 VAC and is designed for normal cabinet mounting. The drive features an IP20 chassis protection level and includes a graphical local control panel along with an RFI Class A1/B filter.
Internal Product Review
The FC-301P15KT4E20H1XGXXXXSXXX is a Danfoss VLT FC 301 automation drive with a 15 kW rating and three-phase power input. Operation is especially practical in standard cabinets thanks to IP20/chassis protection and the Graphical Local Control Panel. 380 to 480 VAC compatibility and the RFI Class A1/B filter make this unit a strong choice for clean, dependable motor control.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
The FC-301P15KT4E20H1XGXXXXSXXX is an AC variable frequency drive produced by Danfoss for the VLT FC 301 Automation Drives series. It belongs to the VLT AutomationDrive FC product group and regulates induction-motor speed in material-handling, pump, and fan installations. By modulating output frequency in relation to the incoming mains supply, the unit provides programmable acceleration, deceleration, and constant-torque operation without mechanical throttling, supporting efficient energy use and controlled production cycles.
This model delivers a continuous mechanical output of 15 kW, equivalent to 20 HP, for mid-range applications that require moderate shaft power. The three-phase power input accepts a mains supply of 380 - 480 VAC, eliminating the need for external phase conversion. The unit has IP20 chassis protection, which prevents incidental contact with internal components while allowing installation inside a suitable control cabinet. Heat is managed within standard A, B, or C frames, and the standard cable entries accommodate typical gland plates. The drive does not include an integral mains disconnect or input fuses, so suitable supply protection must be installed upstream. Its output control supports adjustable motor speed and torque across operating cycles while reducing reliance on mechanical flow-control devices.
Electromagnetic interference is reduced by an integrated RFI Class A1/B filter. Local operation and diagnostic access are provided through the graphical local control panel, which presents operating values and drive parameters through a visual interface. The drive uses normal cabinet mounting for A, B, and C frames, allowing it to fit the corresponding enclosure arrangements. Dynamic braking hardware is omitted through the absence of a brake chopper, so regenerative energy must be handled by compatible external equipment when the application produces significant braking loads. Adaptation B uses the no-adaptation setting, and the printed circuit boards do not have a protective coating. Standard cable access and the open chassis format allow power, motor, and control wiring to be routed through the cabinet while maintaining separation between signal and power conductors.