4.94 based on 219 reviews

🙶 Product was as advertised, got the machine back up and running at a fraction of OEM price. Delivered on ti... 🙷

FC-301P15KT4131X6830 Danfoss

Ask for Availability

Preparing your secure checkout page...

The Danfoss FC-301P15KT4131X6830 is part of the VLT FC 301 Automation Drives series and has a power rating of 15 kW with a maximum horsepower of 20 HP. This three-phase drive supports 2 analog inputs, 1 analog output with 12-bit resolution, and 2 digital outputs with a maximum current of 40 mA. The drive operates at a mains voltage range of 380 to 480 VAC and can handle a maximum motor cable length of 75 meters unshielded.

Warranty
Wake Industrial Warranty

Quote Request Form:

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The FC-301P15KT4131X6830 is an AC variable frequency drive produced by Danfoss as part of the VLT FC 301 Automation Drives series. Within the VLT AutomationDrive FC product group, it is used with three-phase induction motors to vary speed by adjusting output frequency and voltage. The device is installed in control cabinets where precise modulation of motor operation supports conveyors, pumps, and fans in automated plants. Its variable-speed control can match motor performance to changing process demands while maintaining stable operation across the connected machinery.

The inverter connects to industrial mains at 380–480 VAC and delivers up to 15 kW of continuous power, corresponding to 20 HP. It tolerates temporary load surges with an overload capacity of 160% for 1 min/10 min, allowing brief accelerations without tripping. The carrier frequency reaches 32 kHz, which reduces motor noise and improves the current waveform. The three-phase topology draws balanced current and is suitable for industrial three-phase power systems. Shielded motor leads can be run up to 50 m, while unshielded leads can extend to 75 m before reflected-wave voltage limits are approached. A safe torque off input draws 50 mA rms at 24 V for connection to machine safety circuits.

The control terminal block provides two analog inputs with 10-bit resolution and a maximum sourcing demand of 30 mA, enabling speed, torque, or process-variable references from PLCs. One analog output is available with 12-bit resolution for feedback signals such as motor current or output frequency. Discrete signaling is handled through two digital inputs rated for 28 V DC and two digital outputs that can sink or source up to 40 mA. The shortest recognized input pulse width is 4.5 ms, so signals requiring faster response should be transmitted through a suitable fieldbus rather than the standard terminals. These analog and digital connections allow the drive to exchange commands, operating states, and process data with an external control system.

Analog Input Max Current
30 mA
Analog Input Resolution
10 bit
Analog Inputs
2
Analog Output Resolution
12 bit
Analog Outputs
1
Digital Input Max Voltage
28 V DC
Digital Output Max Current
40 mA
Digital Outputs
2
Frequency Output Max
32 kHz
Horse Power
20 HP
Mains Voltage
380 - 480 VAC
Max Shielded Motor Cable
50 m
Max Unshielded Motor Cable
75 m
Minimum Pulse Width
4.5 ms
Overload Classification
160% for 1 min/10 min
Power Phase
Three Phase Power
Power Rating
15 KW
Product Group
VLT AutomationDrive FC
Series Identifier
301
Sto Input Current @24 V
50 mA rms

Frequently Asked Questions about FC-301P15KT4131X6830:

Q: What is the maximum horse power supported by the FC-301P15KT4131X6830 drive?

A: The FC-301P15KT4131X6830 drive can supply up to 20 HP for motor operations.

Q: What is the power rating of the Danfoss FC-301P15KT4131X6830 drive?

A: This unit features a power rating of 15 KW, making it suitable for demanding automation applications.

Q: What is the maximum length allowed for shielded motor cables with this drive?

A: The FC-301P15KT4131X6830 supports a maximum shielded motor cable length of 50 meters.

Q: How many analog inputs are available on the FC-301P15KT4131X6830, and what current can they handle?

A: This model offers two analog inputs, each capable of handling up to 30 mA.

Q: What mains voltage and power phase does the FC-301P15KT4131X6830 require?

A: The drive operates with a three phase power supply between 380 and 480 VAC.


Internal Product Review

  • ‘‘The FC-301P15KT4131X6830 is a Danfoss VLT FC 301 automation drive built for 15 kW operation on 380 to 480 VAC mains. Three-phase power support and 160% overload capability for 1 min/10 min give the drive very solid load-handling performance in demanding applications. Two analog inputs and 12-bit analog output resolution support precise signal control, making the unit a strong choice for dependable automation service.’’

Motion Industries logo
3M logo
IBM logo
Gexpro Logo
Caterpillar logo
NASA logo
Ford logo
Vallen logo