FC-301P15KT2134L2941 Danfoss
Wake Industrial LLC is not an authorized distributor of this product.
No Tariffs On US Orders- Straightforward Pricing: No Rush Fees, No Credit Card Fees
The Danfoss FC-301P15KT2134L2941 is part of the VLT FC 301 Automation Drives series and delivers a power rating of 15 kW or 20 HP. It operates with a mains voltage of 200 to 240 VAC, supports three phase power, and has a peak input current of 81 A. The drive features a maximum output frequency of 590 Hz and an overload capacity of 150% for one minute within ten-minute intervals.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
The FC-301P15KT2134L2941 is an AC variable frequency drive produced by Danfoss and supplied within the VLT FC 301 Automation Drives series. The unit belongs to the VLT AutomationDrive FC product group and is engineered to regulate induction-motor speed in automated process equipment, conveyors, and pump systems. By adjusting output frequency rather than using mechanical throttling, the drive improves energy use and enables closed-loop control that matches motor torque to varying load demands.
Electrical ratings determine how the drive interfaces with plant power. It accepts 200 – 240 VAC three-phase mains and delivers a continuous shaft power of 15 kW (20 HP) while drawing a rated input current of 54 A. The rated output current reaches 59.4 A, supporting applications that need sustained torque under nominal load. When fed from a 230 V bus the converter processes an apparent power of 23.7 kVA, so upstream protection devices must be sized accordingly. Three-phase topology keeps current balanced across all lines, and a power-up rate of 1 start per minute limits thermal stress on semiconductors during frequent cycling.
Protective and performance margins complete the electrical profile. The inverter modulates motor speed up to 590 Hz and tolerates transient load by supplying 150 % for 1 min / 10 min of rated torque. During acceleration the output stage delivers 89.1 A peak, while the input bridge can draw 81 A. A warning occurs at 405 V DC; a trip follows at 410 V. The braking chopper cuts in at 390 V DC to dissipate surplus energy. Fault strength is shown by a 100 000 A RMS short-circuit rating. Motor leads may reach 50 m when shielded or 75 m if unshielded. Continuous duty creates 624 W of loss that must be vented. These properties, tied to the 301 identifier, match the objectives of the VLT AutomationDrive FC group.