The Danfoss FC-301P15KT2134L2707 is part of the VLT FC 301 Automation Drives series and operates with a mains voltage range of 200 to 240 VAC on three phase power. It has a power rating of 15 kW or 20 HP and a rated output current of 59.4 Amps. The drive features a maximum output frequency of 590 Hz, supports up to 50 meters of shielded motor cable, and is designed for an overload capacity of 150 percent for one minute every ten minutes.
Internal Product Review
The FC-301P15KT2134L2707 is a Danfoss VLT FC 301 automation drive rated for 15 kW on 200 to 240 VAC mains. Starting torque of 160% for 60 s and a 590 Hz maximum output frequency give this unit strong low-speed response and broad application flexibility. A 150% overload capacity for 1 min/10 min makes this drive a very capable choice for demanding motion and process duty.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
The FC-301P15KT2134L2707 is an AC variable-frequency drive manufactured by Danfoss for the VLT FC 301 Automation Drives series. It converts fixed three-phase mains power into a controlled, pulse-width-modulated output for automated conveyors, pumps, fans, and other motor-driven equipment. This output allows the connected motor to operate at the speed and torque requested by the process without relying on mechanical throttling. The drive also provides controlled acceleration and deceleration, helping machinery respond smoothly when operating commands change.
The drive is rated for 15 kW of mechanical shaft power and has an apparent power rating of 23.7 kVA. It operates from a 200–240 VAC supply with a nominal input current of 54 A and a rated output current of 59.4 A. The output frequency can reach 590 Hz, making the unit suitable for compatible high-speed motors. Overload handling permits a 150% overload for 1 minute every 10 minutes, with input current reaching 81 A and output current reaching 89.1 A during that operating condition. Three-phase operation helps distribute the electrical load evenly across the incoming phases. Internal power conversion losses produce up to 624 W of heat, which is directed to the heat sink. Cabinet airflow must remove this heat while maintaining suitable operating temperatures around the drive.
High starting demands are supported by a stalled-shaft capability of 160% for 60 seconds. A torque rise time of 1 ms helps the drive respond quickly when the connected motor experiences a sudden load increase. Shielded motor cables can extend up to 50 m while supporting the stated electromagnetic compatibility limits. Power-up cycles are limited to one per minute to reduce stress on the DC-link capacitors. For rapid stopping, the DC link supplies a dynamic brake through a 390 V DC contact. Protective logic issues a warning at 405 V DC, allowing the controller to respond before the 410 V DC overvoltage alarm is activated.