FC-301P11KT4134L2920 Danfoss
Wake Industrial LLC is not an authorized distributor of this product.
The Danfoss FC-301P11KT4134L2920 is part of the VLT FC 301 Automation Drives series and has a power rating of 11 kW with 15 horsepower. It operates on three phase power at 380 to 480 VAC and supports a maximum output frequency of 590 Hz. This drive features an energy efficiency class of IE2 and can withstand an intermittent overload of 160 percent for one minute within every ten minutes.
Internal Product Review
The FC-301P11KT4134L2920 is a Danfoss VLT FC 301 automation drive rated at 11 kW with three-phase 380 to 480 VAC input. Fast control response from a 1 ms flux torque rise time and 160% starting torque gives the drive strong performance during demanding load transitions. A 590 Hz maximum output frequency makes this unit a very capable choice for high-speed automation duty.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
The FC-301P11KT4134L2920 is an AC variable-frequency drive produced by Danfoss for the VLT FC 301 Automation Drives series. Deployed in plant automation, it modulates induction motor speed so pumps, fans, and material-handling equipment match real-time load requirements instead of running at a fixed mains frequency. The unit provides a dedicated power stage for machinery used throughout general industry, where adjustable motor speed can reduce unnecessary energy consumption and improve process control.
It accepts a three-phase mains supply of 380–480 VAC and converts this input into a regulated output rated at 11 kW, equivalent to 15 hp at the shaft. The inverter can raise the output frequency to 590 Hz, while flux mode is limited to 300 Hz, allowing a choice between constant-torque and field-weakening operation. High starting requirements are supported by a torque reserve of 160% for 60 seconds and an intermittent overload capacity of 160% for one minute in every ten. Dynamic events are handled by a 1 ms torque rise under flux control and a 10 ms rise when VVC+ is selected. Full-current service is maintained at 45 °C, and overall efficiency meets the IE2 benchmark. Control inputs tolerate up to 28 V DC on the digital terminals, aligning with standard PLC output cards.
Protective logic issues a bus alarm at 820 V DC to limit stress on the DC link. The drive delivers rated performance at elevations up to 1000 m above sea level without derating, supporting installation in elevated facilities. Power lugs accept conductors up to 10 mm², providing sufficient capacity for the rated input and output current. Motor leads may be routed through shielded cable runs of up to 50 m, while unshielded runs may extend to 75 m before carrier-related losses increase. These cable limits help maintain stable motor operation and reduce the risk of excessive electrical interference in panel-mounted applications.