The Danfoss FC-301P11KT2134L2940 is part of the VLT FC 301 Automation Drives series and has a power rating of 11 kW with a 15 HP output. It operates on three phase, 200 to 240 VAC mains voltage and supports a maximum output frequency of 590 Hz with a max motor cable length of 75 meters unshielded. The drive has an apparent power of 18.4 kVA at 230 V and features a power factor greater than 0.98.
Internal Product Review
The FC-301P11KT2134L2940 is a Danfoss VLT FC 301 automation drive with an 11 kW power rating. Operation on 200 - 240 VAC and a true power factor of ≥0.9 supports efficient integration in demanding drive applications. Strong speed control capability makes the unit a very appealing option, especially with a 590 Hz maximum output frequency.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
The FC-301P11KT2134L2940 is a Danfoss variable-frequency drive in the VLT FC 301 Automation Drives series. In automated plants, it converts fixed three-phase power into a controllable output that allows controllers to adjust motor speed, reduce mechanical stress, and match process demand. The unit is intended for general-purpose induction motor control on 200 to 240 VAC networks.
This model draws up to 18.4 kVA of apparent power when operated on its rated supply line. The input accepts three-phase power and maintains a displacement power factor above 0.98, while the true power factor remains at 0.9 or higher; these values indicate minimal reactive loading on the supply. Its inverter bridge provides a continuous motor output of 11 kW, which corresponds to 15 HP. Output frequency reaches 590 Hz with standard vector control and 300 Hz in flux mode, providing a wide motor speed range. Pulse inputs are read at up to 110 kHz, allowing the drive to process high-resolution encoder or flow feedback. The digital output can source 40 mA, and the maximum diode voltage on that circuit is 28 V DC, supporting an external relay. Only one power-up per minute is permitted to protect the DC-link capacitors from excessive thermal cycling.
The brake chopper activates at 390 V DC to manage regenerated motor energy. At 405 V DC, the unit issues a high-voltage warning and indicates that DC-bus voltage is present; an overvoltage alarm disconnects the drive at 410 V DC. Phase imbalance must remain within 3.0% to avoid excessive DC-link ripple. Shielded motor cables may extend up to 50 m, while unshielded cables may extend up to 75 m without exceeding applicable electromagnetic compatibility or voltage-drop limits. During motor braking, the drive can absorb regenerated energy and dissipate it through an external resistor when the brake chopper activates. Installation clearances and cable routing must follow the applicable FC 301 mechanical guidelines.