4.94 based on 219 reviews

🙶 We have never had a problem in the almost 20 years we have dealt with Wake. We would recommend them to any... 🙷

FC-301P11KT2131H4556 Danfoss

Ask for Availability

Preparing your secure checkout page...

The Danfoss FC-301P11KT2131H4556 is part of the VLT FC 301 Automation Drives series and supports a mains voltage of 200 to 240 VAC for three phase power. This drive delivers a power rating of 11 kW, has an efficiency at rated current of 0.96, and provides up to 15 horsepower. Its maximum output frequency is 590 Hz, and it allows for a maximum shielded motor cable of 50 meters or unshielded cable of 75 meters.

Warranty
Wake Industrial Warranty

Quote Request Form:

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The FC-301P11KT2131H4556 is a variable frequency drive manufactured by Danfoss as part of the VLT FC 301 Automation Drives series. It controls the speed of three-phase induction motors by adjusting output frequency and voltage, allowing automated equipment to match changing mechanical demand without mechanical throttling. The drive provides fundamental process control functions, including braking circuitry and monitoring signals, for machinery connected to low-voltage distribution networks. These capabilities support regulated motor operation in conveyors, pumps, fans, and other equipment that requires adjustable speed or torque.

The power section accepts a nominal input of 200 – 240 VAC through three-phase power lines. With a 208 V supply, the apparent power demand is 16.6 kVA, while operation at 230 V raises the demand to 18.4 kVA. The inverter supplies a continuous mechanical output of 11 kW, so upstream protection devices must be suitable for the connected load. A displacement power factor greater than 0.98 keeps reactive current low, and the true power factor remains at or above 0.9 during rated operation. These power characteristics allow the drive to regulate motor output while limiting unnecessary current demand from the incoming supply.

Conversion efficiency reaches 0.96 at rated current, directing most of the input energy to the motor. Standard control mode permits an output frequency of up to 590 Hz, while flux mode is limited to 300 Hz to support stronger torque control at low speeds. DC-link supervision issues a high-voltage warning at 405 V DC and an overvoltage alarm at 410 V DC. Dynamic braking engages when the DC-link voltage reaches 390 V DC. Shielded motor cables are limited to 50 m, while unshielded motor cables may extend to 75 m without exceeding the permitted installation lengths. An input phase imbalance threshold of 3.0% protects the rectifier from uneven loading. Power must not be cycled more than once per minute because repeated energization can overheat the DC-link capacitors.

Apparent Power (208 V)
16.6 kVA
Apparent Power (230 V)
18.4 kVA
Brake Active Voltage
390 V DC
Displacement Power Factor
>0.98
Efficiency At Rated Current
0.96
Flux Mode Max Frequency
300 Hz
High-voltage Warning
405 V DC
Horse Power
15 HP
Mains Voltage
200 - 240 VAC
Max Output Frequency
590 Hz
Max Power-ups Per Minute
1
Max Shielded Motor Cable
50 m
Max Unshielded Motor Cable
75 m
Overvoltage Alarm
410 V DC
Phase Imbalance Limit
3.0%
Power Phase
Three Phase Power
Power Rating
11 KW
Product Group
VLT AutomationDrive FC
Series Identifier
301
True Power Factor
≥0.9

Frequently Asked Questions about FC-301P11KT2131H4556:

Q: What is the maximum output frequency of the FC-301P11KT2131H4556 drive?

A: The FC-301P11KT2131H4556 provides a maximum output frequency of 590 Hz.

Q: What are the power rating and horsepower of the FC-301P11KT2131H4556?

A: This model offers a power rating of 11 kW and delivers 15 horsepower.

Q: What mains voltage and power phase does the FC-301P11KT2131H4556 support?

A: The drive operates with a mains voltage range of 200 to 240 VAC in a three-phase configuration.

Q: What is the maximum shielded motor cable length for the FC-301P11KT2131H4556?

A: The maximum allowable shielded motor cable length is 50 meters for this drive.

Q: What is the efficiency of the FC-301P11KT2131H4556 at rated current?

A: This model achieves an efficiency of 0.96 at rated current.


Internal Product Review

  • ‘‘The FC-301P11KT2131H4556 is a Danfoss VLT FC 301 automation drive for three-phase systems on 200 - 240 VAC mains. Efficiency at rated current of 0.96 and a displacement power factor above 0.98 support clean, efficient operation in demanding panels. A 590 Hz max output frequency gives the 15 HP drive impressive flexibility for high-performance automation.’’

Motion Industries logo
3M logo
IBM logo
Gexpro Logo
Caterpillar logo
NASA logo
Ford logo
Vallen logo