4.94 based on 219 reviews

🙶 a+ fast delivery 🙷

FC-301P11KT2131F2087 Danfoss

Ask for Availability

Preparing your secure checkout page...

The Danfoss FC-301P11KT2131F2087 is part of the VLT FC 301 Automation Drives series and operates on a mains voltage of 200 to 240 VAC with three phase power. This drive features a power rating of 11 kW or 15 horsepower and supports up to 12 bit analog output resolution. The control card handles loads of 15 mA at 10 V and 200 mA at 24 V, while the device allows for maximum shielded motor cable lengths of 50 meters.

Warranty
Wake Industrial Warranty

Quote Request Form:

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The FC-301P11KT2131F2087 is an AC variable frequency drive manufactured by Danfoss for the VLT FC 301 Automation Drives series. The unit modulates motor voltage and frequency to adjust shaft speed in automated conveyors, centrifugal pumps, and general process equipment. By integrating speed control and protective monitoring in a single enclosure, the drive helps reduce mechanical throttling and align motor energy consumption with real-time load demand.

It delivers 11 kW of continuous electrical power, equal to 15 HP, so it supports medium-horsepower induction motors without derating. The converter accepts 200–240 VAC from a three-phase power supply, and the input stage tolerates line deviations of ±10%. An internal DC-link monitor issues a warning at 405 V DC, allowing the motor speed to be reduced before the bus capacitors reach the alarm threshold. The control card provides a 12-bit analog output for feedback tasks and furnishes two auxiliary sources: a 10 V reference that can supply 15 mA and a 24 V source rated at 200 mA. Logic terminals provide a 40 mA digital sink, while a form-C relay handles AC-1 loads of 240 V at 2 A. Phase imbalance protection de-energizes the inverter when the three mains phases differ by more than 3.0%. The startup logic restricts power cycling to one event per minute to help preserve component life.

An overvoltage alarm is triggered at 410 V DC, forcing a controlled coast stop before semiconductor limits are exceeded. Motor leads may run up to 50 m when shielded or 75 m when unshielded, allowing flexible cabinet placement while keeping dV/dt within motor insulation ratings. The logic stage can pulse notification devices at 32 kHz, which is suitable for high-speed counter inputs in PLCs and supports real-time status signaling. Shielding on shorter cable runs also helps control electrical noise around sensitive control wiring, while the longer unshielded allowance provides additional flexibility where electromagnetic interference is less restrictive.

Analog Output Resolution
12 bit
Control Card 10 V Load
15 mA
Control Card 24 V Load
200 mA
Digital Output Current
40 mA
High-voltage Warning
405 V DC
Horse Power
15 HP
Mains Voltage
200 - 240 VAC
Max Digital Output Freq
32 kHz
Max Phase Imbalance
3.0%
Max Power-ups
1/min
Max Shielded Motor Cable
50 m
Max Unshielded Motor Cable
75 m
Overvoltage Alarm
410 V DC
Power Phase
Three Phase Power
Power Rating
11 KW
Product Group
VLT AutomationDrive FC
Relay Ac-1 Load
240 V AC, 2 A
Series Identifier
301
Supply Voltage Tolerance
±10%

Frequently Asked Questions about FC-301P11KT2131F2087:

Q: What is the operating mains voltage for the FC-301P11KT2131F2087 drive?

A: The FC-301P11KT2131F2087 operates on a mains voltage range of 200 - 240 VAC.

Q: What is the maximum horsepower rating of the FC-301P11KT2131F2087?

A: This drive provides up to 15 horsepower, allowing it to handle substantial motor loads in automation applications.

Q: What is the analog output resolution of the Danfoss FC-301P11KT2131F2087?

A: The analog output on this drive features a 12-bit resolution for precise signal control.

Q: What is the permitted maximum length of shielded motor cable for the FC-301P11KT2131F2087?

A: The maximum length for a shielded motor cable connected to this model is 50 meters.

Q: What is the highest digital output frequency supported by the FC-301P11KT2131F2087?

A: The FC-301P11KT2131F2087 supports a maximum digital output frequency of 32 kHz.


Internal Product Review

  • ‘‘The FC-301P11KT2131F2087 is a Danfoss VLT FC 301 automation drive rated at 11 kW for 200 to 240 VAC service. Three-phase power support and ±10% supply voltage tolerance make panel integration straightforward in demanding automation systems. A 32 kHz maximum digital output frequency stands out for precise control performance.’’