4.94 based on 219 reviews

🙶 First-time customer with Wake Industrial. The ordering process was completely seamless. The part that we o... 🙷

134N6160 Danfoss

In-Stock, Ships 3-5 Days
No Hidden Fees Rush or Credit Card
No Tariffs On US Orders

Internal Product Review

The Danfoss 134N6160 is a VLT FC 301 automation drive engineered for 7.5 kW output and 380 to 480 VAC operation. Three-phase power input and RFI Class A1/B filtering support clean, dependable performance in industrial drive systems. IP20/chassis protection makes this drive a strong choice for controlled cabinet installations.

Sell Part
Have a part to sell?
Warranty
Wake Industrial Warranty

Quote Request Form:

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The 134N6160 is a variable frequency drive produced by Danfoss for the VLT FC 301 Automation Drives series. Intended for cabinet installation in general-purpose process equipment, it converts fixed-frequency supply power into a modulated output for controlling three-phase induction motors. This conversion allows a PLC or distributed control system to regulate motor speed and coordinate torque with changing load demands. Variable-speed operation can also reduce unnecessary energy consumption when pumps, conveyors, or HVAC fans operate below their maximum capacity. The drive is suitable for applications that require accurate motor control within a compact industrial control enclosure.

The drive accepts an input voltage range of 380–480 VAC from a three-phase power network, making it compatible with common industrial mains supplies without an autotransformer. Its inverter provides a continuous output rating of 7.5 kW, which corresponds to 10 HP. This power range supports small to midsize motors used in material-handling systems, building utilities, and process machinery. Heat dissipation and wiring clearances follow normal cabinet-mounting requirements for A, B, and C frames, allowing the unit to be installed near appropriately spaced contactors and circuit breakers. An integrated RFI Class A1/B filter reduces conducted electromagnetic emissions from the switching power stage. Proper grounding, shielded motor cables, and the required installation practices remain important for maintaining electromagnetic compatibility.

The optional communication slot contains a Powerlink MCA 123 module, which provides deterministic Ethernet communication with higher-level controllers. No adaptation module is installed in slot B, and the remaining C0, C1, and D option positions are empty. Conductors enter through standard cable entries, supporting conventional routing of mains, motor, and control wiring inside the cabinet. The drive has uncoated control boards, so it should be housed in a clean, dry enclosure that protects its electronics from condensation, conductive dust, and corrosive airborne contaminants. Its IP20 chassis enclosure prevents accidental finger contact with hazardous internal components but does not protect against water. The unit does not include a brake chopper, so applications that require dynamic braking must use an appropriate external arrangement. An LCP keypad, a dedicated mains switch, and a separate mains input option are also not included.

A Option
Powerlink MCA 123
Adaptation B
No adaptation
B Option
No B Option
Brake - Safe Stop
No brake chopper
C0 Option MCO
No C0 Option
C1 Option
No C1 Option
Cable Entries
Standard
D Option
No D Option
Horse Power
10 HP
LCP
No LCP
Mains Option
No Mains Option
Mains Voltage
380 - 480 VAC
Mounting
Normal Cabinet Mounting - A, B, and C Frame
PCB Coating
Not Coated
Power Phase
Three Phase Power
Power Rating
7.5 kw
Product Group
VLT AutomationDrive FC
Protection Level
IP20 / Chassis
RFI Filter
RFI Class A1/B
Series Identifier
301

Frequently Asked Questions about 134N6160:

Q: What is the power rating of the Danfoss 134N6160 drive?

A: The 134N6160 VLT FC 301 Automation Drive provides a power rating of 7.5 kW, allowing it to control motors up to this capacity.

Q: What mains voltage is required for the 134N6160 VLT FC 301 Automation Drive?

A: This drive operates on a mains voltage range of 380 to 480 VAC, supporting power supplies within this interval.

Q: What type of power phase does the Danfoss 134N6160 support?

A: The 134N6160 model is designed for three-phase power systems, making it suitable for industrial applications.

Q: What is the protection level of the 134N6160 Automation Drive?

A: The protection level for the 134N6160 is IP20 with a chassis mount, which offers basic protection against solid objects.

Q: What type of RFI filter is included in the Danfoss 134N6160 drive?

A: This automation drive features a built-in RFI filter rated as Class A1/B for electromagnetic interference reduction.

Motion Industries logo
3M logo
IBM logo
Gexpro Logo
Caterpillar logo
NASA logo
Ford logo
Vallen logo