Internal Product Review

The VLT 3060 is a Danfoss variable speed drive with 0-120/0-500 Hz output frequency and 0-100% of mains voltage output. A 0.96 efficiency rating and 0.9/1.0 power factor support clean, efficient performance in demanding motor control applications. Extended installation flexibility comes from a 300 m maximum motor cable length, a strong advantage for distributed industrial systems.

Sell Part
Have a part to sell?
Warranty
Wake Industrial Warranty

Quote Request Form:

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The VLT 3060 is a variable frequency drive produced by Danfoss as part of the VLT 3000 Variable Speed Drives series. This AC inverter is installed between the plant power bus and a three-phase induction motor, where it modulates the supplied voltage to control the speed of conveyors, pumps, and material-handling equipment without mechanical throttling or gear changes. By delivering a controlled pulse-width-modulated output, the unit allows control systems to adjust motor torque, acceleration, and deceleration profiles to match process demands.

With an operating efficiency of 0.96, the drive minimizes heat loss while delivering the commanded power level. Its output frequency spans 0 to 120 Hz in standard mode and extends to 0 to 500 Hz for applications requiring high-speed or very-low-speed operation. Motor circuit protection is provided by a 150 A prefuse, and the input section accepts a symmetrical three-phase supply of 3 × 380/400/415/440/460/500 V ±10%. Despite its enclosure weight of 323 lb, the unit can be mounted in a suitable industrial cabinet. The drive operates with a supply frequency of 50 or 60 Hz and produces rated motor voltages ranging from 380 V to 500 V. Its output voltage can be adjusted from 0 to 100 percent of the incoming supply voltage.

The switching devices inside the inverter operate at a maximum carrier frequency of 4.5 kHz, balancing acoustic noise with semiconductor losses. The drive accommodates motor leads up to 300 m long with a maximum cross-sectional area of 70 mm², while the supply side permits conductors with a cross-sectional area of up to 120 mm². Programmable acceleration and deceleration ramps ranging from 0.1 to 3600 seconds allow precise control of startup and stopping stresses. A displacement power factor of 0.9/1.0 keeps reactive demand low on the supply transformer. Available settings include rated motor frequencies of 50, 60, 87, or 100 Hz, allowing the voltage-to-frequency profile to remain consistent across the full output voltage range.

Carrier Frequency Limit
4.5 kHz
Efficiency
0.96
Max Input Cable Area
120 mm²
Max Motor Cable Area
70 mm²
Max Motor Cable Length
300 m
Output Frequency
0-120 / 0-500 Hz
Output Voltage
0-100% of mains voltage
Power Factor
0.9/1.0
Pre-fuse
150 A
Ramp Time
0.1-3600 s
Rated Motor Frequency
50/60/87/100 Hz
Rated Motor Voltage
380/400/415/440/460/500 V
Supply Frequency
50/60 Hz
Supply Voltage
3 x 380/400/415/440/460/500 V ±10%
Unit Weight
323 lb

Frequently Asked Questions about VLT 3060:

Q: What is the maximum output frequency provided by the VLT 3060 drive?

A: The VLT 3060 drive allows an output frequency range of 0-120 Hz or up to 0-500 Hz, enabling a wide speed control for motors.

Q: Which rated motor voltages are compatible with the VLT 3060?

A: The rated motor voltage supported by this model includes 380, 400, 415, 440, 460, and 500 V.

Q: What is the energy efficiency of the Danfoss VLT 3060 drive?

A: The VLT 3060 drive's efficiency is 0.96, minimizing energy losses during operation.

Q: What is the maximum allowed motor cable length for the VLT 3060?

A: This drive supports a maximum motor cable length of 300 meters, accommodating installations that require long cable runs.

Q: What is the adjustable ramp time range for the Danfoss VLT 3060?

A: The VLT 3060 features a ramp time adjustment from 0.1 to 3600 seconds, allowing flexible acceleration and deceleration settings.