4.94 based on 219 reviews

🙶 First-time customer with Wake Industrial. The ordering process was completely seamless. The part that we o... 🙷

VLT 3052 Danfoss

In-Stock, Ships 3-5 Days

Preparing your secure checkout page...

The Danfoss VLT 3052 is part of the VLT 3000 Variable Speed Drives series and delivers a shaft output of 37 kW in CT mode and 45 kW in VT mode. This drive features IP20 and IP54 weights of 54 kg and 69 kg, an efficiency of 0.96, and supports maximum motor cable lengths of 300 meters. It is rated for output currents up to 154 A at 200/230V in VT mode and includes DIN 44081 thermistor standard.

Warranty
Wake Industrial Warranty

Quote Request Form:

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The VLT 3052 is an AC inverter manufactured by Danfoss for the VLT 3000 Variable Speed Drives series. By modulating the output frequency and voltage, the unit allows PLCs or stand-alone controllers to match motor speed with process demand in pumps, fans, and material-handling equipment. Its role in industrial automation is to improve energy use, reduce mechanical wear, and provide adjustable torque across a wide operating range.

Under constant-torque duty, the drive delivers 130.0 A at 200/230 V, 73.0 A at 380/415 V, and 65.0 A at 440/500 V. These current limits indicate the maximum continuous load the connected motor can receive without thermal derating. The corresponding shaft capability reaches 37.0 kW, linking the electrical output to the mechanical power available at the motor shaft. Overall conversion efficiency is 0.96, so only 4% of the input energy is lost as heat inside the cabinet. A discharge wait time of 4 minutes is required before service work begins, allowing the DC-link capacitors to discharge to a safe level. The control logic restricts input starts to two per minute to protect the semiconductors from repetitive inrush current. Motor temperature monitoring follows the DIN 44081 thermistor standard, giving the drive the data needed to trip before the winding insulation is overstressed.

Variable-torque applications permit a higher phase current of 154.0 A at 200/230 V, 88.0 A at 380/415 V, and 78.0 A at 440/500 V, enabling centrifugal loads to accelerate quickly. In this mode, the inverter can deliver up to 45.0 kW to the motor shaft. Motor leads may extend to 300 m without exceeding the drive-side voltage-drop guidelines, allowing the motor to be installed farther from the drive. The IP20 version weighs 54.0 kg, while the IP54 enclosure weighs 69.0 kg when greater protection from dust and water is required. Compliance with a vibration test level of 0.7 g supports installation on machinery exposed to moderate dynamic loading.

Ct Output Current (200/230v)
130.0 A
Ct Output Current (380/415v)
73.0 A
Ct Output Current (440/500v)
65.0 A
Ct Shaft Output
37.0 kW
Discharge Wait Time
4 min
Efficiency
0.96
Input Starts Per Min
2/min
Ip20 Weight
54.0 kg
Ip54 Weight
69.0 kg
Max Motor Cable
300 m
Thermistor Standard
DIN 44081
Vibration Test
0.7 g
Vt Output Current (200/230v)
154.0 A
Vt Output Current (380/415v)
88.0 A
Vt Output Current (440/500v)
78.0 A
Vt Shaft Output
45.0 kW

Frequently Asked Questions about VLT 3052:

Q: What is the CT output current of the Danfoss VLT 3052 at 200/230V?

A: The VLT 3052 provides a CT output current of 130.0 A at 200/230V for demanding applications.

Q: What is the VT shaft output rating of the VLT 3052 variable speed drive?

A: This model features a VT shaft output up to 45.0 kW for variable torque loads.

Q: What efficiency rating does the Danfoss VLT 3052 achieve?

A: The VLT 3052 is designed with an efficiency rating of 0.96, helping reduce energy consumption.

Q: What is the maximum motor cable length supported by the VLT 3052?

A: For motor cables, the VLT 3052 supports lengths up to 300 meters.

Q: How long is the discharge wait time for the VLT 3052?

A: A discharge wait time of 4 minutes is required before performing maintenance on the VLT 3052.


Internal Product Review

  • ‘‘The VLT 3052 is a Danfoss variable speed drive delivering 37.0 kW constant-torque shaft output with 0.96 efficiency. Support for motor cable runs up to 300 m and compliance with DIN 44081 thermistor standard make the drive a strong choice for reliable industrial motor control.’’

Motion Industries logo
3M logo
IBM logo
Gexpro Logo
Caterpillar logo
NASA logo
Ford logo