175H4135
Wake Industrial LLC is not an authorized distributor of this product.
No Tariffs On US Orders- Straightforward Pricing: No Rush Fees, No Credit Card Fees
The 175H4135 is a variable speed drive made by Danfoss. Part of the VLT 3000 Variable Speed Drives series, it operates at a rated power of 2 HP and supports output frequencies up to 500 Hz, programmable for flexibility. The device is designed with protection class options ranging from IP00 to IP54.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
The 175H4135 variable speed drive by Danfoss gives motors exact control and safety. The efficient sinusoidal current flow of this drive makes sure that the motor runs smoothly. The device comes with a standard control card and is made to be easy to use and integrate in industrial automation settings.
The 175H4135 variable speed drive can manage frequencies between 0 and 500 Hz or between 0 and 120 Hz, depending on the configuration. It offers rated motor voltages of 200, 220, and 230 V and rated motor frequencies of 50, 60, 87, and 100 Hz. A thermistor to DIN 44081 and electronic thermal motor safety are built into the drive. The unit has ground fault safety and can switch the output on and off many times without making faults, so it can reliably control the motor. For flexible start and stop patterns, ramp times can be changed from 0.1 to 3600 seconds. At full load, the system has an efficiency of 0.96 and a power factor of 0.9 on the whole. It also comes with a three-wire start/stop control and can only go through two start/stop cycles per minute. The digital programmable control has advanced configuration choices that let you fine-tune how the motor works. For easy use, there are four fixed speeds, and the torque characteristics can be programmed to fit your needs.
With DC braking, the 175H4135 speed drive can stop quickly and gives you 160% of the motor's torque for short amounts of time. The system lets the user program start and slip compensation so that it works best in a variety of situations. Notably, the system is designed to have basic data settings built in, which makes setup easier. The VLT 3003 Series makes sure that different apps work reliably and efficiently.
Frequently Asked Questions about 175H4135:
Q: Why does the 175H4135 use ground fault protection?
A: Ground fault protection in the VLT 3003 Series ensures safety by preventing electrical hazards. It safeguards against faults that could damage equipment or harm operators.
Q: Does the 175H4135 have programmable ramp-up times?
A: Yes, the VLT 3003 Series allows adjustable ramp-up times from 0.1 to 3600 seconds. This enables precise control over motor start-up for varying operational needs.
Q: How does the 175H4135 manage motor thermal protection?
A: The VLT 3003 Series features integrated electronic thermal motor protection and a thermistor to DIN 44081. These ensure reliable motor safety by preventing overheating during operation.
Q: Do the ramp times affect the 175H4135 performance?
A: Ramp times control the smoothness of motor start and stop sequences. Adjustable from 0.1 to 3600 seconds, they help optimize performance and protect equipment.
Q: Why is the 175H4135 efficient at full load?
A: The VLT 3003 operates at 0.96 efficiency at 100% load. This high efficiency minimizes energy consumption and lowers operational costs.