4.95 based on 202 reviews

🙶 Great response and customer service. Back-order item was shipped sooner than expected as well. 🙷

175H2904 Danfoss

In-Stock, Ships 3-5 Days
No Hidden Fees Rush or Credit Card
No Tariffs On US Orders

Internal Product Review

The 175H2904 from the VLT 3000 Variable Speed Drives series by Danfoss offers a high efficiency of 96% at full load and supports a rated output power of 2.2 kW. Designed for 3-phase 380/400/415 V input with ±10% tolerance, it provides stable operation and easy integration. This model stands out for its minimal power loss and reliable performance in demanding industrial environments.

Sell Part
Have a part to sell?
Warranty
Wake Industrial Warranty

Quote Request Form:

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The 175H2904 is a variable frequency drive manufactured by Danfoss within the VLT 3000 Variable Speed Drives series. Intended for AC motor control in production lines, conveyors, and pump systems, the unit modulates applied voltage and frequency so plant controllers can match motor speed to real-time load demands. It connects directly to three-phase mains and fits standard panel-mounting slots, providing a compact method for replacing mechanical throttling with electronic regulation in industrial automation.

On the input side, the converter accepts a three-phase supply of 380/400/415 V with a ±10% tolerance and operates on industrial grids at 50/60 Hz. From this supply, it delivers a rated shaft power of 2.2 kW, supported by a continuous output current of 4.8 A. Electrical conversion losses are kept low, and operating efficiency reaches 96% at full load, reducing heat buildup in control cabinets. When motor torque rises briefly, the input section can draw 5.6 A continuously and up to 6.2 A for 60-second intervals, while the inverter side supplies 5.3 A during the same overload period. The analog reference port has an impedance of 10 kΩ to protect upstream PLC analog outputs. Six digital inputs are powered by an internal 24 VDC source rated at 140 mA.

The inverter can produce a fundamental frequency of up to 120 Hz, allowing overspeed operation with suitably rated motors. The drive has a power loss of 100 W at maximum load, which helps determine the ventilation needed in the control cabinet. Full-load performance is maintained at ambient temperatures up to 40 °C; above this temperature, derating is required to protect the semiconductors. For field wiring, the drive supports unshielded motor cables up to 1000 ft long without exceeding applicable motor insulation limits for voltage rise rates. Short-term current capacity allows the converter to respond to temporary load increases while maintaining controlled motor operation.

Analog Voltage Input Impedance
10 kΩ
Digital Input Supply
24 VDC (140 mA max)
Efficiency (100% Load)
96%
Input Current (60 S)
6.2 A
Input Current (rated)
5.6 A
Input Supply Voltage
3-Phase 380/400/415 V (±10%)
Max Ambient Temp (full Load)
40°C
Max Motor Cable Length (unshielded)
1000 ft
Max Output Frequency
120 Hz
Output Current (60 S)
5.3 A
Output Current (rated)
4.8 A
Output Power (rated)
2.2 kW
Power Loss At Max Load
100 W
Supply Frequency
50/60 Hz

Frequently Asked Questions about 175H2904:

Q: What is the rated output power capacity of the Danfoss 175H2904 drive?

A: The 175H2904 VLT 3000 drive supports a rated output power of 2.2 kW for connected motors.

Q: What input voltage range does the VLT 3000 175H2904 drive require for operation?

A: This drive operates on a three-phase 380/400/415 V input supply with a ±10% voltage tolerance.

Q: What efficiency does the 175H2904 VLT 3000 achieve when fully loaded?

A: At full load, the efficiency of the 175H2904 model reaches 96%.

Q: What is the maximum output frequency supported by the Danfoss 175H2904?

A: The maximum output frequency for this drive is 120 Hz, allowing control of high-speed motors.

Q: What is the maximum ambient temperature allowed for full load operation of the 175H2904 drive?

A: The 175H2904 can safely operate at a maximum ambient temperature of 40°C under full load conditions.