4.95 based on 202 reviews

🙶 Product was as advertised, got the machine back up and running at a fraction of OEM price. Delivered on ti... 🙷

175H1739 Danfoss

In-Stock, Ships 1-2 Days
No Hidden Fees Rush or Credit Card
No Tariffs On US Orders

Internal Product Review

The 175H1739 is a Danfoss VLT 3000 variable speed drive with 460 V motor voltage and 60 Hz motor frequency. Efficiency rated at 0.96 and IP54 enclosure protection support dependable performance in industrial service. A 2.2 kW shaft output gives the unit solid capability for controlled drive applications.

Sell Part
Have a part to sell?
Warranty
Wake Industrial Warranty

Quote Request Form:

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The 175H1739 is an AC variable frequency drive produced by Danfoss for the VLT 3000 Variable Speed Drives series. It modulates three-phase mains power to let automation controllers vary induction motor speed, making it suitable for conveyors, pumps, and other constant-torque loads that require adjustable flow or throughput on the plant floor. An enclosure rating of IP54 protects live components against dust and splashing water, allowing the drive to be installed on the production floor instead of in a dedicated motor control center room.

This model delivers electrical conversion with an efficiency of 0.96, so only 4% of the supplied power is dissipated as heat. The drive accepts an input supply of 460 V at the standard 60 Hz frequency and provides the motor windings with a continuous output current of 4.8 A. Under these conditions, it can furnish 4.1 kVA of apparent power, while the motor output rating of 2.2 kW indicates the available mechanical shaft power. Protective upstream wiring uses a 16 A pre-fuse, and the terminals accept 2.5 mm² conductors. This pairing keeps cable heating within limits at the listed current. The controller’s internal switching logic allows two commanded speed changes per minute, a constraint that prevents thermal stress on its IGBT bridge. Steady-state thermal loading is 130 W, a value that helps determine the required enclosure ventilation.

Transient demands are handled by a peak output current of 7.7 A, which the inverter can sustain long enough to overcome inertial or breakaway torque without exceeding semiconductor limits. During those surges, apparent power climbs to 6.7 kVA, so downstream contactors and filters must be rated accordingly. The drive has an overall mass of 11 kg, which eases mounting while providing enough metal for heat spreading and structural stiffness.

Cable Cross-section
2.5 mm²
Efficiency
0.96
Enclosure Rating
IP54
Input Switching Rate
2/min
Motor Frequency
60 Hz
Motor Voltage
460 V
Output Current
4.8 A
Output Power
4.1 kVA
Peak Output Current
7.7 A
Peak Output Power
6.7 kVA
Power Loss
130 W
Pre-fuse
16 A
Shaft Output
2.2 kW
Unit Weight
11 kg

Frequently Asked Questions about 175H1739:

Q: What cable cross-section is required for the 175H1739 VLT 3000 drive?

A: The Danfoss VLT 3000 175H1739 drive supports a cable cross-section of 2.5 mm².

Q: What is the efficiency of the Danfoss 175H1739 VLT 3000 drive?

A: The 175H1739 offers an efficiency rating of 0.96 for reliable energy usage.

Q: What is the enclosure rating of the 175H1739 VLT 3000 variable speed drive?

A: This model features an IP54 enclosure rating, providing protection against dust and splashing water.

Q: What is the shaft output power of the Danfoss 175H1739 drive?

A: The 175H1739 VLT 3000 delivers a shaft output of 2.2 kW.

Q: What is the peak output current provided by the 175H1739 VLT 3000 drive?

A: The peak output current for this drive is rated at 7.7 A.