VACON0100-3L-0105-4-HVAC-R02+IP54 Danfoss
Wake Industrial LLC is not an authorized distributor of this product.
No Tariffs On US Orders- Straightforward Pricing: No Rush Fees, No Credit Card Fees
Current response time:
4 Minutes
50 Seconds
The Danfoss VACON0100-3L-0105-4-HVAC-R02+IP54 is part of the VACON 100 Industrial Drives series and features 2 analog inputs, 6 digital inputs, and 1 analog output. This drive offers a maximum output frequency of 320 Hz, a displacement power factor greater than 0.98, and has an IP54 (Type 12) protection class.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
The VACON0100-3L-0105-4-HVAC-R02+IP54 is a variable frequency drive manufactured by Danfoss and supplied under the VACON 100 Industrial Drives series. It converts fixed-frequency mains power into a regulated output that lets building automation systems vary motor speed for pumps, fans, and compressors. By controlling torque electronically, the drive helps balance airflow and chilled-water circuits while lowering mechanical stress during starts and stops.
The power section accepts a three-phase supply and delivers a modulated output up to 320 Hz, so constant-torque loads can run well above the base motor frequency when required. The enclosure is sealed to IP54 / Type 12, protecting the electronics against dust and splashing water for direct machine-side mounting. Control connectivity includes 2 analog inputs that read process variables with 0.1% resolution. It also includes 6 digital inputs with a minimum impedance of 5 kΩ for direct connection to PLC sourcing cards. A single analog output reproduces feedback signals with 0.1% resolution and can drive loads with an impedance as low as 500 Ω. A 24 V, 250 mA auxiliary rail powers external sensors without requiring an additional supply.
The command chain provides ±1% analog input accuracy, ensuring that setpoints are interpreted within tight limits. Feedback is returned through an analog output that maintains ±2% analog output accuracy across its operating range. Power quality is supported by a power factor greater than 0.98, minimizing the reactive current drawn from the mains. Radiated and conducted noise complies with Category C2 EMC emissions, permitting installation on industrial feeders without additional filtering. This emissions category supports use in commercial and light-industrial power networks when the required installation practices are followed. The accurate command and feedback channels help the controller respond consistently to changing pressure, temperature, or flow demands in HVAC equipment.