The Danaher HZ172A607 is part of the Timers and Controllers series and operates on a 120 VAC, 50/60 Hz supply. It features a maximum count speed of 500 counts per minute, a minimum count of 1, and a maximum count of 40. The controller offers 2 SPDT instant and 2 SPDT delayed output contacts, rated at 10 amps at 120 VAC, and has a dial lock feature.

Warranty
Wake Industrial Warranty

Quote Request Form:

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The HZ172A607 is a mechanical preset counter produced by Danaher within the Timers and Controllers series. It registers discrete step inputs, advances an internal cam, and switches relay contacts when the user-set value is reached, allowing batch control or machine indexing in automated processes. A panel-mounted dial provides direct preset selection, and the built-in clutch mechanism synchronizes the cam with the count register.

The device accepts a 120 VAC, 50/60 Hz mains feed for its drive motor and control circuits. Its counting window runs from a minimum of 1 count to a maximum of 40 counts, and it tracks pulses at a maximum rate of 500 counts/min without loss. A dial lock prevents inadvertent knob movement during operation. When the preset is reached, two instantaneous SPDT relays and two delayed SPDT relays change state. Each contact set carries up to 10 A at 120 VAC, so the counter can directly drive solenoids, motor starters, or indicator lamps. The delayed path closes one count after the instantaneous path, providing the one-count differential required for staged sequencing.

The electromechanical section requires a step-input on-time of 40 ms and at least 80 ms of off-time between pulses to guarantee full indexing. At each transition, the step motor draws 26 VA of inrush power and settles to a 10.5 VA holding level through the clutch coil. The coil reaches pull-in within 50 ms. Initial energization of the clutch draws a peak of 16 VA, after which holding power falls to 10.5 VA. If the preset is changed or a cycle must restart, the counter resets within 500 ms at the highest setting and returns all relays to their home positions. During reset, the delayed contacts return to their home positions one step before the instantaneous contacts, maintaining the one-count differential during repetitive operation.

Clutch Coil Hold
10.5 VA
Clutch Coil Inrush
16 VA
Clutch Pull-in
50 ms
Count Maximum
40
Count Minimum
1
Count Speed
500 counts/min max
Delayed Differential
1 count early
Feature
Dial Lock
Output Contacts
2 SPDT instant + 2 SPDT delayed
Output Rating
10 A @ 120 VAC
Reset Time
500 ms at max setting
Step Input Off Time
80 ms
Step Input On Time
40 ms
Step Motor Burden
26 VA inrush
Supply
120 VAC, 50/60 Hz

Frequently Asked Questions about HZ172A607:

Q: What is the required supply voltage for the HZ172A607 timer?

A: The HZ172A607 operates with a supply voltage of 120 VAC at 50/60 Hz.

Q: What is the maximum count speed capability of the HZ172A607?

A: This timer supports a maximum count speed of 500 counts per minute.

Q: What types of output contacts are available on the HZ172A607?

A: The unit is equipped with two SPDT instant and two SPDT delayed output contacts.

Q: What is the purpose of the dial lock feature on the HZ172A607?

A: The dial lock feature on this model helps prevent accidental changes to timer settings.

Q: What output rating does the HZ172A607 timer provide?

A: The HZ172A607 can switch loads up to 10 A at 120 VAC.


Internal Product Review

  • ‘‘The Danaher HZ172A607 is a timer and controller with a 1 to 40 count range suited for precise count-based operation. The 2 SPDT instant plus 2 SPDT delayed output contacts and 10 A at 120 VAC rating support dependable panel integration. A dial lock feature and 50 ms clutch pull-in make the unit a strong choice for repeatable count control.’’

Motion Industries logo
3M logo
IBM logo
Gexpro Logo
Caterpillar logo
NASA logo
Ford logo
Vallen logo