HP50-295
Wake Industrial LLC is not an authorized distributor of this product.
No Tariffs On US Orders- Straightforward Pricing: No Rush Fees, No Credit Card Fees
The Danaher HP50-295 controller, part of the Timers and Controllers series, operates on a voltage range of 20-264 VAC/DC. It features a maximum continuous load current of 350 mA for AC, a 5.7 V maximum on-state voltage drop, and a power-up time delay of 9 seconds. The controller's operating temperature spans -25°C to +70°C.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
The HP50-295 from Danaher drops into the Timers and Controllers class with a lineup built for managing automation where timing and load matters. The power range opens wide, running on 20-264 VAC/DC, so not locked into just one voltage setup. That kind of range lets it fit in factories or panels running a mix of supply lines. Running on AC, this controller keeps steady with a maximum continuous load current at 350 mA, while DC operation brings a 200 mA max. These numbers are important on lines where current swings without much warning.
Durability steps up too, since this unit keeps up with ambient swings from -25°C to +70°C. It's tough enough for equipment racks inside hot plants or in places that sit close to freezing. The on-state voltage drop tops at 5.7 V, which avoids wasting too much voltage when the circuit's closed. Power-up doesn’t hit instantly, as there’s a 9-second time delay baked in. This might not matter much for some jobs, but on automated lines, a delay stops sudden rushes that can trip other controls. The sense distance runs 0 to 8 mm, so it's got room for positioning, like near sensors or actuators that are never exactly flush.
Smaller loads don’t throw the controller either, with a minimum continuous load current at just 5 mA, and surge moments covered by a 2 A inrush current strength. There’s a soft touch with 1.5 mA of leakage current, avoiding unintended triggers down the line. Installation needs a watchful hand for wiring, but the voltage and frequency span means fewer worries around compatibility for AC (45-65 Hz) or simple DC setups (0 Hz). Put all that together and the HP50-295 brings stable performance for time-based switching. Its specs fit general machinery, conveyor lines, and energy-saving panels where durability, flexible input, and dependable on/off control show real value.
Frequently Asked Questions about HP50-295:
Q: What is the operating voltage range of the HP50-295 controller?
A: The HP50-295 controller operates on a voltage range of 20-264 VAC/DC.
Q: What is the maximum continuous load current for AC operation?
A: The maximum continuous load current for AC operation is 350 mA.
Q: What is the operating temperature range of the HP50-295 controller?
A: The operating temperature range is from -25°C to +70°C.
Q: What is the power-up time delay of the HP50-295?
A: The power-up time delay is 9 seconds.
Q: What is the on-state voltage drop of the HP50-295?
A: The maximum on-state voltage drop is 5.7 V.