DG106A3 Danaher
Wake Industrial LLC is not an authorized distributor of this product.
MPN:
No Tariffs On US Orders- Straightforward Pricing: No Rush Fees, No Credit Card Fees
-
In-Stock, Ships 1-2 Days
Current response time:
3 Minutes
46 Seconds
The Danaher DG106A3 is part of the Timers and Controllers series and operates with a supply voltage of 120 VAC or 120 VDC at 50/60 Hz. It features on-delay and interval timing modes, a DPDT output relay rated at 10 A at 120 VAC, and withstands temperatures from 0°C to 60°C. The unit offers power interruption immunity of 20 milliseconds and has a panel cutout size of 92.0 by 44.0 mm.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
The DG106A3 is a panel-mount electronic timer produced by Danaher within the Timers and Controllers series. It governs time-based switching sequences in automated machinery, allowing conveyors, heaters, or solenoids to energize or de-energize after a defined delay without relying on a PLC for simple timing functions. By combining a built-in power supply and change-over relay, the unit fits directly into control panels and supports repetitive operations where precise interval or delay execution is required.
The timer accepts a control source of 120 VAC (50/60 Hz) or 120 VDC, eliminating the need for additional converters in panels already wired for these levels. Users can choose between On-Delay and Interval operation, enabling either delayed energization or fixed-length pulse output from a single device. Its relay contacts are rated for 10 A at 120 VAC, so the timer can switch most fractional-horsepower motors or resistive loads directly. The internal relay is a DPDT configuration, providing two isolated change-over circuits for simultaneous control of independent loads. Mechanical installation is simplified by a standard rectangular panel opening of 92.0 x 44.0 mm, which matches many DIN front-panel cutouts.
Behind the bezel, the housing projects only 50.8 mm, conserving depth in shallow enclosures. The unit operates from 0 °C up to 60°C, covering typical factory ambient ranges without additional heating or cooling. It withstands mains dips lasting 20 ms without losing its timing cycle, reducing nuisance resets during brief power disturbances. Surge suppression withstands transients up to 600 V peak with a 50 µs rise, protecting the control electronics from nearby inductive loads. For installations subject to mechanical motion, the timer endures 2.5 g sinusoidal vibration, maintaining reliable contact alignment during operation.
Frequently Asked Questions about DG106A3:
Q: What timing modes are available on the DG106A3 timer from Danaher?
A: The DG106A3 supports both on-delay and interval timing modes.
Q: What supply voltage is required for the DG106A3 timer and controller?
A: This model operates with a supply voltage of 120 VAC (50/60 Hz) or 120 VDC.
Q: What type and rating of output relay does the DG106A3 timer use?
A: The output relay on the DG106A3 is a DPDT type and is rated for 10 A at 120 VAC.
Q: What is the transient immunity rating of the DG106A3 timer and controller?
A: The DG106A3 features a transient immunity of up to 600 V peak for 50 microseconds.
Q: How does the DG106A3 timer handle brief power interruptions?
A: With power interruptions up to 20 ms, the DG106A3 maintains operation without reset.