The Danaher 80Q2A60901 is part of the Timers and Controllers series and features a DPDT contact form with a push-to-test manual operator. It operates with a supply voltage of 120 VAC at 60 Hz, supports a maximum time setting of 256 seconds, and provides resistive output rated at 10 amps at 250 VAC. The timer offers an electrical life of 100,000 operations and a fixed time accuracy of plus or minus 5%.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
The 80Q2A60901 is a fixed-range time-delay relay produced by Danaher for the Timers and Controllers series. Built for cabinet installation, the unit introduces an adjustable pause between an energizing command and contact transfer, allowing conveyors, heaters, or starters to operate in a controlled sequence without additional PLC code. By coordinating motion and load events, this relay supports industrial automation applications that require consistent timing and electrical isolation. Its integral timing circuit controls power-side switching while the logic side remains at low signal levels, reducing wiring complexity in distributed control panels.
Incoming control power is 120 VAC at 60 Hz, so the module can use a standard U.S. power source without a transformer. A front dial selects a delay within a full-scale range of 25.6 s to 256 s, and the selected interval is maintained within ±5% of the set value. When de-energized, the contacts disengage after 30 ms, minimizing arc duration when inductive loads are connected. On the output side, the double-pole circuit carries up to 10 A at 250 VAC for purely resistive loads, giving the relay enough capacity to switch small motors, solenoid valves, or lamps. Temperature and voltage variations have negligible effects on timing drift across the usable delay range.
The relay uses a DPDT changeover arrangement, providing two isolated circuits that operate simultaneously. A push-to-test button allows manual verification of contact operation before the relay is placed into service. Long-term durability is supported by an electrical life of 100,000 operations, while the spacing between the coil and contacts provides an initial insulation resistance of 100 MΩ. After the programmed delay expires, the coil must remain de-energized for 75 ms to complete a full reset. If a reset is requested during an active timing cycle, a minimum reset period of 150 ms is required. Repeated cycles maintain timing accuracy within ±1.5%, supporting consistent dwell periods during recurring machine operations. The device operates from -10 °C to 40 °C without derating, allowing use in common indoor industrial control cabinets.