4.95 based on 206 reviews

🙶 Great service, they have the parts i needed in stock. 🙷

XTL-FA-01 Copley Controls

In-Stock, Ships 3-5 Days
No Hidden Fees Rush or Credit Card
No Tariffs On US Orders

Internal Product Review

The XTL-FA-01 is a Copley Controls accessory filter for drive systems, rated for 20 Adc and 373 Vdc. Common-mode inductance of 220 uH and differential inductance of 82 uH/phase support cleaner power handling and stable system performance. A well-engineered addition for demanding motion applications, especially with 40 Adc peak capability.

Sell Part
Have a part to sell?
Warranty
Wake Industrial Warranty

Quote Request Form:

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The XTL-FA-01 is a passive line filter produced by Copley Controls for the Copley Controls Accessories series. It installs on the DC bus of servo drives, where it blocks common-mode and differential switching noise before those signals reach the power source. By attenuating fast signal edges, the device protects upstream power supplies and prevents interference with nearby control instrumentation in industrial automation systems.

At the input terminals, a common-mode inductance of 220 µH works with a differential inductance of 82 µH per phase to increase impedance to high-frequency components while leaving the DC level unaffected. The header uses a 5.0 mm pitch and provides five positions for supply, return, and protective earth conductors. These pins support a continuous current of 20 A DC at up to 373 V DC, matching the front-end capability of compatible Copley servo amplifiers. Energy passes through copper tracks with a resistance of only 27 mΩ per leg, limiting I²R losses even at full load. The four-position output block passes the same current and voltage to the drive, while a typical rise and fall time of 500 ns keeps switching transitions within the filter’s operating range. All connected wiring must have a 600 V insulation rating to meet the board clearance requirements.

During transient events, the filter tolerates a surge current of 40 A DC for 1 second, allowing it to withstand motor inrush or regenerative surges without saturating the core. Cable sets should use 12 AWG conductors to accommodate the overload while fitting the pluggable clamps. The assembly weighs 1 lb 11 oz, allowing DIN-rail or panel mounting beside compact amplifiers. The input connector separates the logic return from the chassis ground, directing incoming noise currents through the laminated core rather than the enclosure metal. This routing helps preserve electromagnetic compatibility during rapid duty-cycle changes without altering the normal DC power path.

Common Mode Inductance (nom)
220 uH
Connector Pitch
5.0 mm
Differential Inductance (nom)
82 uH/phase
Input Connector Positions
5
Max Input Current
20 Adc
Max Input Voltage
373 Vdc
Max Output Current
20 Adc
Max Output Voltage
373 Vdc
Nominal Resistance
27 mOhm/leg
Output Connector Positions
4
Peak Current
40 Adc
Peak Time
1 s
Recommended Wire Gauge
12 AWG
Rise/fall Time (typ)
500 ns
Weight
1 lb 11 oz
Wire Voltage Rating
600 V

Frequently Asked Questions about XTL-FA-01:

Q: What is the maximum continuous input current supported by the XTL-FA-01?

A: The XTL-FA-01 supports a maximum continuous input current of 20 Adc, making it suitable for demanding industrial power applications.

Q: What is the common mode inductance value of the XTL-FA-01 accessory?

A: The XTL-FA-01 has a common mode inductance rating of 220 uH, which helps suppress common mode electrical noise in the connected circuits.

Q: What wire gauge is recommended for wiring the XTL-FA-01?

A: With a recommended wire gauge of 12 AWG, the XTL-FA-01 ensures safe and efficient power transmission.

Q: What is the connector pitch for the XTL-FA-01's terminal blocks?

A: The connector pitch of the XTL-FA-01 is 5.0 mm, designed for reliable terminal block connections.

Q: What is the peak current rating and duration for the XTL-FA-01?

A: The XTL-FA-01 can handle a peak current of up to 40 Adc for 1 second, allowing it to manage temporary current surges without issue.