VT-VSPA1-1-1X-002-30SEC Bosch Rexroth Indramat
Wake Industrial LLC is not an authorized distributor of this product.
MPN: R900934743
Ask for AvailabilityThe Bosch Rexroth Indramat VT-VSPA1-1-1X-002-30SEC is part of the VT-VSPA Proportional Amplifiers series and weighs 0.1 kg. It features a 32-pole male multipoint connection, DIN 41612 Design D connector, and operates at a nominal supply of 24 VDC with a maximum power consumption of 50 VA. The amplifier measures 100 x 160 mm in card size and has a fuse rating of 2.5 A slow-blow.
Internal Product Review
The VT-VSPA1-1-1X-002-30SEC is a proportional amplifier well suited for precise valve control, with a 24 VDC nominal supply and 50 VA max power consumption. The 100 Ω command input resistance and 1 mV/mA actual value scale support stable signal handling and accurate adjustment in closed-loop applications. A 32-pole male multipoint connection with ±25 mA external loadability makes this amplifier a strong choice for dependable integration.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
The VT-VSPA1-1-1X-002-30SEC is a plug-in proportional amplifier card from Bosch Rexroth Indramat in the VT-VSPA Proportional Amplifiers series. The unit mounts as a 100 mm × 160 mm Eurocard and interfaces with valve coils through a single rack connector. In industrial automation, it translates low-power command voltages from a controller into controlled solenoid current, allowing hydraulic proportional valves to follow precise reference signals for pressure and flow regulation on presses, plastic machines, and general motion axes.
The amplifier operates from a nominal system voltage of 24 VDC and remains functional until the supply drops to +22 V or rises to a ceiling of +35 V. Within this span, its internal circuits draw up to 1.8 A, translating to a peak power demand of 50 VA under worst-case loading. These limits set the power budget that must be allocated on the machine’s low-voltage rail and help determine suitable protective devices and wiring sizes. A slow-blow fuse can be installed in line with the card, and its front plate also carries status LEDs for quick diagnostic reference while the 32-pole DIN 41612 backplane connector streamlines installation.
Signal handling features include a command input resistance of 100 Ω, enabling direct interface with PLC analog outputs without excessive loading. The actual value channel uses a scaling of 1 mV/mA, so a 100 mA spool current appears as 100 mV for monitoring or feedback loops. Output driver circuitry can source or sink ±25 mA, allowing control of most NG6 and NG10 proportional solenoids while remaining below the onboard protective fuse rating of 2.5 A with a slow-blow characteristic. The module also conforms to the 100 × 160 mm outline, carries a front-plate height of 128.4 mm, provides a reference voltage of ±9 V for sensor circuits, and, at 0.1 kg, adds minimal mass to the rack.