VT-UK2-3X/VT4451/U50 Bosch Rexroth Indramat
MPN: R900977702
No Tariffs On US Orders- Straightforward Pricing: No Rush Fees, No Credit Card Fees
The Bosch Rexroth Indramat VT-UK2-3X/VT4451/U50 is part of the VT-UK2 Universal Cards series and features a Eurocard format measuring 100 x 160 mm. It operates with a 10 V input and output signal, contains 3 double op-amp packages for a total of 6 operational amplifiers, and has 5 null point potentiometers. The card uses soldered junctions for assembly and is equipped with a DIN 41612 blade connector.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
The VT-UK2-3X/VT4451/U50 is a universal signal-conditioning board produced by Bosch Rexroth Indramat for the VT-UK2 Universal Cards series. Installed in control racks, the card translates low-level sensor data into standardized voltages for industrial automation controllers and valves. By occupying a single Eurocard slot, it serves as a compact analog processing element that simplifies field wiring and parameter adjustment inside hydraulic or motion-control cabinets. That role helps isolate sensitive control inputs from raw field signals that may require scaling or offset correction before they reach the rest of the system.
Physically, the board follows the Eurocard format and measures 100 x 160 mm, so it fits standard 3U rack guides without additional spacers. Signal and power lines pass through a DIN 41612 backplane interface on a Blade Connector, allowing quick installation while maintaining reliable contact resistance. The on-board circuitry uses a 10 V supply delivered through the backplane to feed reference networks and active devices. Using the rack connection for both power and signal routing reduces front-access wiring and keeps the card edge accessible for service in densely populated control cabinets.
Signal processing is handled by 3 double op-amps, giving a total of 6 operational amplifiers that can be arranged as differential inputs, integrators, or active filters depending on jumper positions. Calibration is adjusted through 5 potentiometers, each using a null-point design to correct drift without changing gain. The conditioned channel can source up to 5 mA, which is enough to drive valve electronics while holding the output at the card's fixed 10 V span. Soldered junctions throughout the board hold component leads securely and help maintain low contact resistance under vibration, and the layout supports offset and response adjustments without requiring external signal-conditioning hardware.
Frequently Asked Questions about VT-UK2-3X/VT4451/U50:
Q: What is the input voltage required for the VT-UK2-3X/VT4451/U50 card?
A: This card requires an input voltage of 10 V for operation.
Q: How many operational amplifiers are included on the VT-UK2-3X/VT4451/U50 card?
A: The card features 6 operational amplifiers arranged as 3 double op-amp packages.
Q: How many potentiometers are included on the VT-UK2-3X/VT4451/U50 and what type are they?
A: A total of five null point potentiometers are built into this card.
Q: What are the output signal and output current specifications for the VT-UK2-3X/VT4451/U50?
A: The output signal provided by this card is 10 V with a maximum output current of 5 mA.
Q: What are the card format, size, and connector standard used on the VT-UK2-3X/VT4451/U50?
A: It uses a Eurocard format with dimensions of 100 x 160 mm and a DIN 41612 blade connector.