VT-UK2-3X/VT11985A/U152 Bosch Rexroth Indramat
Wake Industrial LLC is not an authorized distributor of this product.
MPN: R900578969
No Tariffs On US Orders- Straightforward Pricing: No Rush Fees, No Credit Card Fees
The Bosch Rexroth Indramat VT-UK2-3X/VT11985A/U152 is part of the VT-UK2 Universal Cards series and features a Eurocard format with a card size of 100 mm by 160 mm. This card includes 6 operational amplifiers, 5 null point potentiometers, operates at an input and output voltage of 10 V, and has a maximum output current of 5 mA.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
The VT-UK2-3X/VT11985A/U152 is an electronic interface card manufactured by Bosch Rexroth Indramat for the VT-UK2 Universal Cards series. Intended for industrial automation panels, the board conditions low-level sensor signals and drives proportional valves by generating precise reference voltages and currents. Its Eurocard footprint supports quick slide-in mounting within standardized subracks, and the unit can serve as a bridge between transducers, controllers, and power stages in hydraulic or motion-control loops. By occupying only a single slot, it conserves cabinet space and provides flexible configuration options across multiple control axes. This makes it suitable for analog control paths that require stable signal transfer between field devices and higher-level electronics.
The board conforms to the Eurocard outline, giving it a physical height of 100 mm and a length of 160 mm. These dimensions follow the DIN 41 494 printed-circuit standard, which sets hole patterns and guide-rail clearances so multiple cards can share a common 19-inch subrack. The format also allows the card to fit standard guide rails and backplanes used in modular control racks. Signal and power lines exit through a rear-edge Blade Connector, allowing quick removal without disturbing front-panel wiring. A stabilized reference applied at the input feeds trimming networks, and five null-point potentiometers allow sensor offsets to be corrected during setup.
The mating backplane connector follows the DIN 41 612 layout, matching the male blade on the card. Internally, 6 precision operational amplifiers provide buffering, inversion, and gain functions, enabling linear signal conditioning without external stages. After processing, the board delivers an output voltage of 10 V at up to 5 mA, which is suitable for command inputs on proportional valve electronics and servo controllers. Because the input and output ranges are identical, closed-loop systems can use symmetric scaling, and calibration remains straightforward during normal adjustment. This arrangement helps preserve predictable response in feedback circuits that use the same nominal range for incoming and outgoing analog values.
Frequently Asked Questions about VT-UK2-3X/VT11985A/U152:
Q: What card format does the VT-UK2-3X/VT11985A/U152 use?
A: The VT-UK2-3X/VT11985A/U152 is built to the Eurocard format, providing a card size of 100 mm by 160 mm.
Q: What connector style is featured on the VT-UK2-3X/VT11985A/U152 universal card?
A: This model uses a DIN 41 612 blade connector for reliable and standardized card connection.
Q: How many null point potentiometers are available on the VT-UK2-3X/VT11985A/U152 card?
A: It features five null point potentiometers, enabling precise signal adjustment.
Q: How many operational amplifiers are present on the VT-UK2-3X/VT11985A/U152 universal card?
A: This card is equipped with six operational amplifiers integrated on the board.
Q: What are the output current and voltage specifications for the VT-UK2-3X/VT11985A/U152 card?
A: The VT-UK2-3X/VT11985A/U152 supports an output current of 5 mA and an output voltage of 10 V.