4.95 based on 202 reviews

🙶 Excellent to work with and they stand behind their work. I would highly recommend them. 🙷

VT-UK2-3X/ES-E61-A204/U213 Bosch Rexroth Indramat

MPN: R900960475

No Tariffs On US Orders
  • Rated 4.5 (46 total ratings)
  • Straightforward Pricing: No Rush Fees, No Credit Card Fees
Ask for Availability

Preparing your secure checkout page...

The Bosch Rexroth Indramat VT-UK2-3X/ES-E61-A204/U213 is a Eurocard-format universal card from the VT-UK2 Universal Cards series, measuring 100 by 160 millimeters. It features 6 operational amplifiers, 5 null point potentiometers, and supports regulator functions like inverter, Schmitt-Trigger, summator, and differentiator. The card has DIN 41 612 standard connectors with 32 or 64 pins and operates at 15 VDC or 24 VDC.

Quote Request Form:

Warranty
Wake Industrial Warranty

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The VT-UK2-3X/ES-E61-A204/U213 is a plug-in signal conditioning card produced by Bosch Rexroth Indramat for the VT-UK2 Universal Cards series. As a general-purpose electronic module, the card installs in hydraulic drive racks to scale, combine, and shape analog command signals before they reach servo or proportional valve amplifiers. By providing onboard op-amps, potentiometers, and switching functions, it lets the control system adapt reference voltages and feedback loops without a custom printed circuit board. This arrangement is useful where valve command levels and feedback signals must be matched to the surrounding control electronics.

The board follows the Eurocard mechanical format, and its profile of 100 x 160 mm fits standard 3U subracks. I/O enters through connectors that comply with the DIN 41 612 backplane standard, so it can slide into common industrial card cages. A regulated 10 V reference line can supply sensors or serve as a summing point, while 6 operational amplifiers perform gain, inversion, or differentiation. Fine adjustments are made with 5 null point potentiometers, allowing precise centering of valve spool positions or zeroing of transducers without external instruments. The card also hosts inverting, Schmitt-trigger, summing, and differentiator stages that can be wired through solder bridges for custom logic.

Electrical interfacing is flexible because the rear connector can be populated with 32 or 64 pins to match available rack wiring. The onboard power regulators accept either 15 VDC or +24 VDC, allowing use in low-voltage logic enclosures as well as higher-power hydraulic cabinets. For downstream devices, the card sources a buffered 10 V, 5 mA output, which is adequate for most command or feedback lines without overloading the reference rail. A relay terminal pulls in between +17 and +28 V to enable or disable signal paths, allowing simple safety or mode-select circuits with minimal additional hardware. This makes the card suitable for mixed cabinet layouts where signal conditioning and relay control are handled in the same rack.

Card Format
Eurocard
Card Size
100 x 160 mm
Circuit Interconnect
Soldered Junctions
Connector Form
C or D
Connector Pins
32 or 64
Connector Standard
DIN 41 612
Input Voltage
10 V
Null Point Potentiometers
5
Operating Voltage
15 VDC or +24 VDC
Operational Amplifiers
6
Output Signal
10 V; 5 mA
Regulator Functions
Invertor, Schmitt-Trigger, Summator, Differentiator
Relay Call-up Voltage
+17 to +28 V
  • VTUK23XESE61A204U213
  • VT UK2 3X ES E61 A204 U213
  • vt-uk2-3x/es-e61-a204/u213

Frequently Asked Questions about VT-UK2-3X/ES-E61-A204/U213:

Q: What is the card format and size of the VT-UK2-3X/ES-E61-A204/U213?

A: The VT-UK2-3X/ES-E61-A204/U213 card uses the Eurocard format with dimensions of 100 x 160 mm.

Q: What operating voltages are required for the VT-UK2-3X/ES-E61-A204/U213?

A: This card operates with either a 15 VDC or +24 VDC voltage supply.

Q: What type of circuit interconnect does the VT-UK2-3X/ES-E61-A204/U213 use?

A: The VT-UK2-3X/ES-E61-A204/U213 features soldered junctions for its circuit interconnection.

Q: What is the output signal specification for the VT-UK2-3X/ES-E61-A204/U213?

A: Output signals from this card are 10 V at a maximum current of 5 mA.

Q: What built-in regulator functions does the VT-UK2-3X/ES-E61-A204/U213 provide?

A: This model includes regulator functions such as invertor, Schmitt-Trigger, summator, and differentiator.


Internal Product Review

  • ‘‘The VT-UK2-3X/ES-E61-A204/U213 is a Bosch Rexroth Indramat universal card in Eurocard format with DIN 41 612 connector compatibility. With 6 operational amplifiers and regulator functions that include invertor, Schmitt-trigger, summator, and differentiator, the card offers excellent signal-processing flexibility for demanding control applications.’’

Motion Industries logo
3M logo
IBM logo
Gexpro Logo
Caterpillar logo
NASA logo
Ford logo
Vallen logo