The Bosch Rexroth Indramat VT 2000-48 E2 is part of the VT 2000 Proportional Amplifiers series, operating at 24 VDC with an adjustable solenoid current up to 800 mA. Its ramp time can be set between 30 ms to 5 s, and it includes a ±9 V regulated voltage output. It weighs only 0.1 kg.

Warranty
Wake Industrial Warranty
To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

Bosch Rexroth Indramat makes the VT 2000-48 E2. The VT 2000-48 E2's energy efficiency is a key factor in its functionality. That's because it uses less than 25 VA of power and draws less than 1 A of current. This low power consumption—about as low as you can get—helps keep control cabinets cool and industrial systems energy-efficient. By reducing heat production and the need for significant power sources and wiring, you avoid overheating and electrical risks. A safeguard against overcurrent situations is a 2.5 A T (time-delay) fuse built right into the amplifier. This fuse is designed to melt if the current exceeds a specific limit for a set amount of time. That's when it protects the amplifier and other system components from damage. A range of inputs and outputs on the VT 2000-48 E2 lets you accurately control hydraulic systems. One of the essential inputs is a voltage signal between 0 and +9 V that sets the intended position or flow rate of the proportional valve. That input converts the control signal directly into valve action and is linked to a standard potential—usually ground. The amplifier also has a differential input with 100 kΩ input resistance.

By cutting down on common-mode noise, that differential design ensures precise signal transmission. The amplifier can modify ramp time—from as little as 30 ms to 1 or 5 seconds (depending on the jumper setting)—to dynamically control the proportional valve. That means you can make either quick or gradual changes in valve position based on your application's needs. The VT 2000-48 E2's adaptability and integration into larger automation systems are improved by a number of auxiliary functions. One of those is the amplifier's controlled biasing current output, which can be adjusted from 10 mA to 300 mA. That helps the proportional valve overcome deadband and static friction. By fine-tuning the valve's initial response characteristics, you can get the performance you need.

The amplifier also produces a clock frequency output that can be set between 100 and 200 Hz for synchronization with other system components or pulse width modulation (PWM). You get precise control over the solenoid current output, which regulates the electromagnetic actuator of the valve. That output can be set to a maximum of 800 mA with a tolerance of ±10%. You also get voltage and current measurement sockets for monitoring and troubleshooting applications. These outputs, along with a regulated ±9 V voltage output to power additional sensors, make the amplifier a very accurate and versatile tool for hydraulic system management.

Actual current monitor output
0–800 mV = 0–800 mA ±10 mA
Command value monitor output
0 to +6 V (100%); Rin 1 kΩ
Connector type
32‑pin male, DIN 41612 Form D
Current consumption
<1 A
Fuse rating
2.5 A time‑lag
Input 1 (command) voltage range
0 to +9 V (ref. M0)
Input 2 (command) voltage range
0 to +10 V; Rin 100 kΩ
Operating temperature range
0°C to 50°C
Operating voltage
24 VDC (22–35 V, +40%/–5%)
Output biasing current
10–300 mA adjustable via PCB pot R130
Output clock frequency
100 or 200 Hz ±10% (jumper S2)
Power consumption
<25 VA
Ramp time adjustment
30 ms to ~1 s or ~5 s (jumper S1)
Regulated voltage output
±9 V ±1%, up to ±25 mA load
Solenoid output current
Up to 800 mA (+10%/–5%), R20=19.5 Ω
Storage temperature range
-25°C to +85°C
Weight
approx. 0.1 kg

Frequently Asked Questions about VT 2000-48 E2:

Q: What is the current consumption of the VT 2000-48 E2?

A: The VT 2000-48 E2 has a current consumption of less than 1 A, ensuring efficient energy use while performing its tasks.

Q: How precise is the regulated voltage output of the VT 2000-48 E2?

A: The VT 2000-48 E2 provides a ±9 V regulated voltage output with a tight tolerance of ±1%, ensuring stable operation for connected systems.

Q: What is the ramp time adjustment range of the VT 2000-48 E2?

A: The ramp time of the VT 2000-48 E2 is adjustable from 30 ms up to approximately 1 second or 5 seconds, depending on the jumper setting.

Q: What is the maximum solenoid current the VT 2000-48 E2 can handle?

A: The VT 2000-48 E2 can handle a maximum solenoid current of up to 800 mA, with a tolerance of +10% to -5%, suitable for demanding automation applications.

Q: What type of connection does the VT 2000-48 E2 use?

A: The VT 2000-48 E2 uses a 32-pin male connector (DIN 41 612, form D), making it compatible with various industrial systems.


Internal Product Review

  • ‘‘The VT 2000-48 E2 proportional amplifier from Bosch Rexroth Indramat offers a compact and versatile solution for controlling proportional valves. Featuring adjustable parameters such as solenoid current and ramp time, the unit allows for fine-tuning of hydraulic system response. The inclusion of a regulated ±9V output with high accuracy provides a stable power supply for external sensors or circuitry. Integration is facilitated by the standard 32-pin DIN connector. The amplifier's lightweight design is beneficial for space-constrained installations. Overall, this proportional amplifier delivers reliable and precise control for a range of industrial automation tasks.’’