VCH02.2NNN-000RS Bosch Rexroth Indramat
MPN: R912006061
No Tariffs On US Orders- Straightforward Pricing: No Rush Fees, No Credit Card Fees
The Bosch Rexroth Indramat VCH02.2NNN-000RS is part of the VCH IndraControl Terminals series and weighs 0.6 kilograms. It supports an operating voltage of DC 5 V ±0.25 V with maximum input current of 20 mA and power consumption under 90 mA. The unit handles axial loads up to 10 N, radial loads up to 20 N, and can reach speeds of 200 per minute.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
The VCH02.2NNN-000RS is a compact control terminal manufactured by Bosch Rexroth Indramat within the VCH IndraControl Terminals series. As an operator-mounted unit, it provides discrete signal handling for motion platforms and safety interlocks in automated cells. Its circuitry connects directly to logic-level controllers and converts field switch states into clean TTL-compatible signals. By integrating the terminal close to actuators and sensors, wiring runs are shortened and cabinet space is saved, allowing I/O functionality to be distributed across the machine.
The terminal runs on an operating supply of DC 5 V ±0.25 V, aligning with typical backplane voltages in IndraControl racks. Under this supply, it draws up to 20 mA on any individual input, while total draw stays below 90 mA, which minimizes load on the system power rail. Input transitions are captured with a maximum rise or fall time of 2 µs, so status changes are relayed without noticeable latency. A pulse train can be processed up to 5 kHz, meaning shaft-encoded positions and rapid proximity events remain within detectable bandwidth. Logic high is recognized above 2.5 V and logic low below 0.5 V, keeping compatibility with standard CMOS outputs.
The housing withstands axial forces up to 10 N and radial forces up to 20 N, so encoder wheels or stop cams can be mounted directly on the shaft without overloading the bearings. When fitted to rotary fixtures, the internal sensing disc can track rotations up to 200 rpm, while an integral stop switch carries loads from 5 V at 1 mA to 30 V at 1 A for emergency cutoff loops. During transport, the terminal survives shocks of 980 m/s² for 6 ms and endures vibration levels of 50 m/s² across the operating spectrum. With a weight of 0.6 kg, it can be mounted on light brackets without adding excessive inertia.
Frequently Asked Questions about VCH02.2NNN-000RS:
Q: What is the maximum axial load the VCH02.2NNN-000RS terminal can handle?
A: The VCH02.2NNN-000RS terminal supports a maximum axial load of 10 N.
Q: What is the required operating voltage for the VCH02.2NNN-000RS?
A: This terminal operates at a voltage of DC 5 V with a tolerance of ±0.25 V.
Q: What is the maximum input current supported by the VCH02.2NNN-000RS?
A: The max allowable input current for the VCH02.2NNN-000RS is 20 mA.
Q: What is the highest output frequency the VCH02.2NNN-000RS can achieve?
A: The VCH02.2NNN-000RS has a maximum output frequency of 5 kHz.
Q: What is the power consumption of the VCH02.2NNN-000RS terminal?
A: This model consumes less than 90 mA of power during operation.