The Bosch Rexroth Indramat SPM 75-TB is part of the SPM Inverter Modules series. It features dedicated LED indicators for encoder faults, error codes, logic faults, and position status. The module also includes overload, external release, and internal trigger LEDs for clear diagnostics and monitoring.

Warranty
Wake Industrial Warranty

Quote Request Form:

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The SPM 75-TB inverter module is manufactured by Bosch Rexroth Indramat and belongs to the SPM Inverter Modules series. Designed for drive cabinets, it converts DC link power into controlled three-phase output that drives motors in automated machinery. By delivering regulated voltage and frequency, it permits speed and torque control and interfaces with motion controllers. Its compact housing fits beside rectifier and braking components, forming part of a modular power stack used in assembly lines, packaging equipment, and material-handling stations.

Status information is provided through front-panel light-emitting diodes. The encoder diagnostic lamp labeled MMF (Red) turns on when the feedback channel from the motor fails, prompting checks of the sensor cable or alignment. Three error indicators grouped as FC1-FC3 display coded fault sequences so drive, power, or control faults can be isolated without instruments. A system enable path is supervised by the FG (Green) LED; it lights only when an external release signal is present, confirming that safety interlocks are satisfied. The internal trigger condition is shown by FGI (Green), allowing distinction between user-issued and internal gating commands. Drive logic health is monitored through the LF (Red) diode, which illuminates on microprocessor or communication problems. Overcurrent or thermal loading is announced by I2t (Green); once this indicator activates, the controller has integrated current beyond its preset threshold and may limit output until values return.

Additional feedback is provided by the position light, POS (Green), which flashes in step with the calculated motor position so encoder alignment can be checked during setup. Together with the other indicators, it creates a visual diagnostic layer that helps shorten fault tracing and reduce downtime. These built-in displays eliminate the need for separate test modules for routine status checks. The arrangement also keeps the cabinet layout simpler by placing operating information directly on the drive.

Encoder Fault Led
MMF (Red)
Error Code Leds
FC1-FC3
External Release Led
FG (Green)
Internal Trigger Led
FGI (Green)
Logic Fault Led
LF (Red)
Overload Led
I2t (Green)
Position Led
POS (Green)

Frequently Asked Questions about SPM 75-TB:

Q: How does the SPM 75-TB indicate an encoder fault?

A: The SPM 75-TB features an MMF (Red) LED for encoder fault indication.

Q: What indicators are used for error codes on the SPM 75-TB?

A: Three separate LEDs labeled FC1-FC3 display error codes on the SPM 75-TB.

Q: How can external release be confirmed on the SPM 75-TB inverter module?

A: The SPM 75-TB uses a green LED labeled FG to indicate external release status.

Q: What feature of the SPM 75-TB notifies users of a logic fault?

A: An LF (Red) LED is provided to show logic faults on this model.

Q: Which LED on the SPM 75-TB signals an overload event?

A: The SPM 75-TB includes a green I2t LED to indicate overload conditions.


Internal Product Review

  • ‘‘The SPM 75-TB is a Bosch Rexroth Indramat inverter module with clear MMF red encoder-fault indication and LF red logic-fault indication. FG green external-release status and FGI green internal-trigger status simplify commissioning and diagnostics in drive cabinets. A well-executed diagnostic layout makes the module a strong fit for service-focused inverter applications.’’