RND01.1-5-007 Bosch Rexroth Indramat
MPN: R911201035
No Tariffs On US Orders- Straightforward Pricing: No Rush Fees, No Credit Card Fees
The Bosch Rexroth Indramat RND01.1-5-007 is part of the RND Three Phase Mains Chokes series and supports three AC phases. It offers a line voltage of 500 V with a tolerance of plus 10 percent, and operates at a rated frequency of 50 or 60 Hz. This choke features an inductivity of 0.39 mH, has a line current of 20 A, is rated for IP20 protection class, and weighs 3.3 kilograms.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
The RND01.1-5-007 is a mains choke designed by Bosch Rexroth Indramat as part of the RND Three Phase Mains Chokes series. The component is inserted on the line side of servo drives or variable-frequency drives to raise supply impedance, damp line-to-line harmonics, and limit peak currents during network disturbances. By decreasing the slope of the current rise, the choke protects DC link capacitors, mitigates conducted radio-frequency noise, and contributes to the overall electromagnetic compatibility of an automated production cell.
The device handles a 3-phase AC network and presents an inductance of 0.39 mH, producing the required voltage drop to smooth current without excessive power loss. It is rated for a continuous line current of 20 A, so drives drawing up to that level can be connected without derating. With a permissible line voltage of 500 V, the choke matches common 400 V class distribution systems that may experience short excursions, and its iron core remains unsaturated within this range. A rated frequency of 50/60 Hz supports worldwide mains standards. Power conductors can be terminated with 6 mm² ferrule wires or 10 mm² single wires, and a separate 10 mm² ground terminal provides the required protective bonding path.
Thermal and mechanical limits describe suitable mounting conditions. Operation is allowed up to 40 °C ambient, provided natural convection is not obstructed. The housing carries an IP20 degree of protection that prevents accidental finger contact yet requires installation inside a switchgear enclosure. Network voltages may rise by up to +10% without exceeding the insulation rating, which helps preserve inductance linearity and limit core heating. At 3.3 kg, the choke adds minimal mass to DIN-rail assemblies while still offering a low-impedance path for common-mode noise.
Frequently Asked Questions about RND01.1-5-007:
Q: What is the maximum line voltage supported by the RND01.1-5-007 choke?
A: The RND01.1-5-007 mains choke can operate with a line voltage up to 500 V.
Q: How many AC phases does the RND01.1-5-007 support?
A: This model is designed for use with three-phase AC systems.
Q: What is the maximum line current the RND01.1-5-007 can handle?
A: The RND01.1-5-007 has a maximum line current rating of 20 A.
Q: What is the protective class rating of the RND01.1-5-007 choke?
A: This mains choke features an IP20 protective class, providing basic protection against solid objects.
Q: What is the maximum ambient temperature rating for the RND01.1-5-007?
A: It supports a maximum ambient operating temperature of 40 °C.