RLC1-013BAB Bosch Rexroth Indramat
Wake Industrial LLC is not an authorized distributor of this product.
MPN:
No Tariffs On US Orders- Straightforward Pricing: No Rush Fees, No Credit Card Fees
The Bosch Rexroth Indramat RLC1-013BAB is a power cable from the RLC1 Motor Power Cables series. It features a total of 6 conductors, with a cable composition of 4x 0.75 mm² and 2x 0.14 mm², and an ambient reference temperature of 40 °C. The cable has a current capacity per core of 10.4 A and supports a conductor temperature limit of 90 °C.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
The RLC1-013BAB is a flexible motor power lead manufactured by Bosch Rexroth Indramat within the RLC1 Motor Power Cables series. Intended for routing drive output to synchronous or induction motors, the cable forms part of closed-loop automation where stable energy transmission is required. Its construction and conductor sizing match the electrical interfaces of Rexroth drive packages and the part is selected when a dedicated power connection, rather than signal feedback, must be installed inside cabinets or along machine frames.
Classified as a Power Cable, the RLC1-013BAB integrates four power conductors each having a cross-section of 0.75 mm², equivalent to 18 AWG in North American sizing. These cores are combined with a pair of lighter auxiliary wires, producing the composite layout of 4x 0.75 mm² + 2x 0.14 mm². The arrangement permits separation of motor temperature sensors or brake release lines from the main phases without a second harness. Each power core can carry up to 10.4 A, a rating that defines the maximum continuous motor phase current the assembly can sustain when routed in free air and laid out according to Rexroth cable guidelines. The outer jacket and internal insulation are coordinated with this current level to limit resistive heating and maintain dielectric integrity under repetitive acceleration cycles.
Two signal conductors are sized at 0.14 mm², bringing the total number of conductors to 6 and allowing compact bending radii in energy-chain applications. Thermal limits are set against an ambient reference of 40 °C, while the conductor insulation itself tolerates temperatures up to 90 °C before properties deviate from nominal values. When paired with standard RLC connectors, the basic design supports cabinet installations or machine-mounted routing without further derating. The specified dimensions and temperature margins help prevent nuisance drive trips due to voltage drop or insulation stress during routine production shifts.
Frequently Asked Questions about RLC1-013BAB:
Q: What is the cross-sectional area of the main power cores in the RLC1-013BAB cable?
A: The RLC1-013BAB features four power conductors with a cross-section of 0.75 mm² each.
Q: How many conductors are present in the RLC1-013BAB motor power cable?
A: This cable contains a total of six conductors for power and auxiliary purposes.
Q: What is the current capacity per core for the RLC1-013BAB cable?
A: Each conductor in the RLC1-013BAB can safely carry up to 10.4 A of current.
Q: What is the ambient reference temperature rating for the RLC1-013BAB power cable?
A: The maximum allowable ambient reference temperature for this cable is 40 °C.
Q: What is the conductor temperature limit for the RLC1-013BAB cable?
A: The conductor temperature limit for this cable is specified at 90 °C.