The Bosch Rexroth Indramat RL2-521CBT is part of the RL2 Motor Power Cables series. This cable features a cross section of 1.0 mm² and an outer diameter of 12.2 mm, with a torsion design and PUR jacket. It supports a rated voltage of 600/1000 V for power wires and can withstand up to 5,000,000 bending cycles.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
The RL2-521CBT motor power cable is produced by Bosch Rexroth Indramat within the RL2 Motor Power Cables series. This flexible assembly carries three-phase supply energy from drive amplifiers to second-generation synchronous motors in automated machinery. By combining finely stranded copper conductors with a torsion-rated jacket, the cable transfers continuous current and maintains signal integrity while machines execute repetitive, high-speed motion cycles in packaging lines, gantry axes, and other industrial automation devices.
The power conductors inside the cable have a nominal cross-section of 1.0 mm², giving a balance between current-carrying capacity and manageable outer size. They are rated for 600/1000 V, allowing connection to low-voltage inverters without additional insulation. Temperature endurance reaches +90°C when the installation is fixed, so routing through warm control cabinets does not shorten service life. During dynamic operation the cable follows a minimum bending radius of 7.5xD, and its sheath supports up to 5,000,000 flex cycles in torsional and chain applications. Insulation resistance is at least 20 MΩ/km, limiting leakage currents even on long runs. An overall diameter of 12.2 mm simplifies routing through standard energy chains while preserving mechanical robustness.
For moving axes the static portion of the harness can be anchored on a radius of 5xD, preventing strain where the cable transitions from stationary fixtures to energy chains. When motion is continuous, the flexible conductor class withstands ambient peaks of +80°C without insulation cracking. The outer jacket is moulded from PUR (Orange RAL 2003), a material chosen for oil resistance and visibility inside machines. Coupled with a low mutual capacitance of 0.4 nF/m, the design minimises reactive losses between motor phases and keeps drive feedback stable. The cable is tuned for the 2nd motor generation, and its torsion-optimised conductor stranding distributes stress evenly along the length to extend service life.
Frequently Asked Questions about RL2-521CBT:
Q: How many bending cycles can the RL2-521CBT power cable withstand?
A: The RL2-521CBT cable is rated for up to 5,000,000 bending cycles during operation.
Q: What is the jacket material and color of the RL2-521CBT cable?
A: This cable features a PUR jacket with an orange color matching RAL 2003.
Q: What is the dynamic bending radius requirement for the RL2-521CBT cable?
A: The dynamic bending radius of the RL2-521CBT cable is specified as 7.5 times the cable diameter.
Q: What is the conductor cross section of the RL2-521CBT cable?
A: The RL2-521CBT cable has a cross section size of 1.0 mm² for its conductors.
Q: What is the rated voltage for the power wires in the RL2-521CBT cable?
A: The RL2-521CBT cable supports a rated voltage of 600/1000 V for its power wires.