The RL2-024CBB is a motor power cable manufactured by Bosch Rexroth Indramat as part of the RL2 Motor Power Cables series. It has a cross section of 1.0 mm² and supports a rated voltage of 600/1000 V for power wires. The cable is designed for at least 5 million bending cycles, features a PUR jacket in orange, and has a dynamic bending radius of 7.5 times the cable diameter.

Warranty
Wake Industrial Warranty

Quote Request Form:

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The RL2-024CBB is a motor power cable produced by Bosch Rexroth Indramat for the RL2 Motor Power Cables series. Classified under the Rexroth Cable product group, it connects second-generation drive motors to their servo amplifiers. The cable carries three-phase power and auxiliary signals required for controlled motion in assembly lines, robotic axes, packaging equipment, and other automated machinery. Its basic construction provides consistent electrical characteristics and a moderate outside diameter, allowing the cable to fit into standard routing trays and machine cable paths.

The cable contains eight conductors arranged in a 4 × 1.0 mm² + 4 × 0.75 mm² configuration. The four power conductors each have a cross-sectional area of 1.0 mm², while the four smaller conductors carry encoder or brake reference signals. The power conductors are rated for 600/1000 V, allowing them to handle the bus voltages used by compatible industrial drive systems. The auxiliary conductors withstand up to 450/750 V without dielectric failure. A minimum insulation resistance of 20 MΩ/km helps limit leakage current over long cable runs. The outer sheath is made from PUR, which resists oil and protects the cable from abrasion as it moves through plastic carrier chains.

During dynamic operation, the cable supports a minimum bending radius of 7.5 × D, where D represents its outside diameter. Fixed installations permit a tighter minimum bending radius of 5 × D inside control panels or stationary cable routes. Its rated service life exceeds 5 million flex cycles at the stated dynamic bending radius, supporting repetitive movement in pick-and-place equipment and high-speed gantries. The copper conductors tolerate temperatures up to 90 °C in fixed installations and up to 80 °C during continuous movement. An orange outer jacket in RAL 2003 improves cable visibility inside crowded ducts and carrier systems. The flexible sheath and conductor arrangement allow the cable to follow repetitive machine motion while maintaining power delivery and auxiliary signal transmission.

Bending Cycles (min)
5 million
Cable Design
Basic
Cable Type
4x L + 4x 0.75 mm²
Conductor Temp Max (fixed)
90 °C
Conductor Temp Max (flexible)
80 °C
Cross Section
1.0 mm²
Dynamic Bending Radius
7.5xD
Insulation Resistance (min)
20 MΩ/km
Jacket Color
Orange (RAL 2003)
Jacket Material
PUR
Motor Generation
2nd
Product Group
Rexroth Cable
Rated Voltage (power Wires)
600/1000 V
Rated Voltage (signal Wires)
450/750 V
Static Bending Radius
5xD

Frequently Asked Questions about RL2-024CBB:

Q: How many bending cycles can the RL2-024CBB power cable withstand?

A: The RL2-024CBB cable is designed to support at least 5 million bending cycles, making it suitable for demanding dynamic applications.

Q: What is the cable type for the RL2-024CBB model from Bosch Rexroth Indramat?

A: This cable uses a 4x L + 4x 0.75 mm² configuration, allowing for dedicated power and signal transmission lines within the sheath.

Q: What material is used for the jacket of the RL2-024CBB cable?

A: The jacket on the RL2-024CBB is made from PUR, providing excellent abrasion and chemical resistance.

Q: What is the power wire rated voltage for the RL2-024CBB cable?

A: The RL2-024CBB has a rated voltage of 600/1000 V for its power wires, which allows compatibility with high power equipment.

Q: What is the maximum conductor temperature for the RL2-024CBB cable in both fixed and flexible installation conditions?

A: The maximum conductor temperature for the RL2-024CBB is 90 °C when fixed and 80 °C when flexible, supporting a wide range of operational environments.


Internal Product Review

  • ‘‘The RL2-024CBB from Bosch Rexroth Indramat is a robust RL2 Motor Power Cable with a basic design and PUR jacket for excellent durability in industrial environments. Rated for 600/1000 V on power wires and supporting at least 5 million bending cycles, it is well-suited for applications requiring both flexibility and long service life. The combination of dynamic bending performance and high insulation resistance ensures reliable motor connectivity.’’