The Bosch Rexroth Indramat RKL4718 is part of the RKL Motor Power Cables series and features three power conductors and four auxiliary conductors. This cable uses a direct connection with a drive-side connector type RLS0723 and a motor-side termination at Terminal Box RLK1301. It supports up to 5,000,000 bending cycles and operates in temperatures from -30 to 80 degrees Celsius.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
The RKL4718 cable is produced by Bosch Rexroth Indramat and belongs to the RKL Motor Power Cables series. It functions as the primary power link between IndraDrive converters and synchronous motors, carrying three-phase energy and auxiliary signals while tolerating continuous flexing inside cable chains. In automated machining and handling cells, this dedicated motor cable streamlines installation because both the drive-side connector and motor-side terminations are predefined by the manufacturer.
The cable houses 3 power conductors each with a cross-section of 2.5 mm², providing the current-carrying capacity required by mid-range servo axes. A high-cycle design verified for 5,000,000 bending cycles supports rapid-fire motion sequences without conductor fatigue. During dynamic movement, curvature is limited to a minimum of 7.5×D, so energy chains can be specified confidently. On the drive end a keyed RLS0723 (K03) connector is moulded to the sheath, enabling direct plug-in to Rexroth power modules and eliminating field crimping.
When machines are parked or routed statically, the cable can be formed down to 5×D without violating sheath integrity. Internal control wiring is supported by 4 auxiliary conductors, allowing temperature sensors or brakes to share the same run; each auxiliary core is sized at 1.0 mm² to match low-level signal demands. At the motor end, conductors terminate inside the sealed RLK1301 terminal box, reducing on-site wiring time and preserving IP protection. The compound jacket continues to flex reliably from –30 °C up to 80 °C, covering cold-start warehouses and heated production floors alike.
Wake Industrial stocks this cable assembly, and same-day shipping is available for urgent orders. Quotations issued for the RKL4718 remain valid for 30 days. Customers benefit from knowing that the product is in stock when immediate replacement is required.
Frequently Asked Questions about RKL4718:
Q: How many power conductors are included in the RKL4718 motor power cable?
A: The RKL4718 cable features three power conductors, allowing efficient power transmission to compatible motors.
Q: How many auxiliary conductors does the RKL4718 cable provide?
A: This model is equipped with four auxiliary conductors, suitable for handling additional control or signal lines.
Q: What is the bending cycle capacity for the RKL4718 power cable?
A: The RKL4718 is designed to withstand up to 5,000,000 bending cycles, offering high durability in dynamic applications.
Q: What is the minimum dynamic bending radius required for installing the RKL4718 cable?
A: The dynamic bending radius for the RKL4718 cable is specified as 7.5 times the cable diameter (7.5×D).
Q: What is the operating temperature range for the RKL4718 power cable?
A: The RKL4718 cable can operate in temperatures ranging from -30°C to 80°C.