The Bosch Rexroth Indramat RKL4467 is part of the RKL Motor Power Cables series and features a PUR matte jacket that is halogen-free. This cable supports both drag chain use and a rated voltage of 600 V AC for power and control. Its conductor resistance is 3.30 ohms per kilometer and the maximum wire temperature is 90 degrees Celsius for fixed installation.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
The Bosch Rexroth Indramat RKL4467 cable belongs to the RKL Motor Power Cables series and is supplied for servo-drive installations in automated production cells. As a motor power cable, it routes three-phase energy and auxiliary control cores from the drive controller to the motor, enabling coordinated motion and feedback functions within industrial automation systems. Its design follows Rexroth system cabling conventions.
Under fixed routing conditions the minimum bend radius is 5 × D, while dynamic assemblies that move in cable tracks must observe a bend radius of 7.5 × D. Internally the conductor set is specified as 4x6.0 mm² + (2x1.0)StC + (2x1.5)StC, giving three-phase power, protective earth and paired shielded control cores in one sheath. Direct current loss is limited by a conductor resistance of 3.30 Ω/km, and charge transfer between adjacent cores is held to 0.8 nF/m of capacitance, which supports low-noise encoder channels. The cable operates in drag-chain applications and its PUR, adhesion-free matte jacket limits abrasion. Both the power and control cores are rated for a nominal line potential of 600 V AC, allowing integration with standard Rexroth inverter outputs.
The thermal envelope is defined by a conductor temperature of 90 °C when the cable is clamped and a reduced limit of 80 °C during continuous flexing, so cabinet layouts and chain guides must maintain these values to avoid insulation fatigue. With an overall diameter of 18.5 mm the RKL4467 fits standard metric glands and drag-chain separators without overstressing fill ratios. The halogen-free construction minimises corrosive gas release during an electrical fault, a feature that supports stricter safety rules in enclosed machine spaces.
Frequently Asked Questions about RKL4467:
Q: What is the minimum bending radius for fixed installations of the RKL4467 power cable?
A: The RKL4467 cable can be safely bent to a radius as small as 5 times the cable diameter when installed in a fixed position.
Q: Is the RKL4467 power cable designed for use in drag chain systems?
A: Yes, the RKL4467 is suitable for use in drag chain applications.
Q: What material is used for the outer jacket of the RKL4467 cable?
A: The outer jacket of the RKL4467 is made from PUR, which is adhesion-free and has a matte finish.
Q: What is the conductor resistance of the RKL4467 at 20°C per kilometer?
A: The maximum conductor resistance at 20°C for the RKL4467 power cable is 3.30 Ω per kilometer.
Q: Is the RKL4467 cable halogen-free in its construction material?
A: The RKL4467 power cable is manufactured without halogen, making it halogen-free.