MPN:
The Bosch Rexroth Indramat RKL4415 is part of the RKL Motor Power Cables series and features a cable composition of 4x16 mm² plus 2x(2x1.5 mm²), with a PUR jacket and an outer diameter of 25.5 mm. This cable has an operating voltage of 600 V AC, conductor resistance of 1.21 Ohm/km at 20 degrees Celsius, and a discharge capacity of 1.2 nF/m.
Internal Product Review
The RKL4415 is a robust motor power cable from Bosch Rexroth Indramat, featuring a 4x16 mm² plus 2x(2x1.5 mm²) composition and a PUR jacket for excellent mechanical durability. Its conductor resistance of 1.21 Ohm/km and 600 V AC operating voltage make it reliable for demanding power transmission applications. This cable stands out with its flexibility and long service life in industrial environments.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
The RKL4415 is a motor power cable produced by Bosch Rexroth Indramat within the RKL Motor Power Cables series. The cable links IndraDrive servo drives to synchronous motors, transmitting three-phase power and auxiliary voltages in automated machinery. Its conductor layout and insulation are dimensioned for medium-voltage industrial environments, allowing reliable energy delivery to axis groups, gantries, and processing stations while withstanding repetitive motion inside drag-chain assemblies.
The cable core uses a 4x16 mm² + 2x(2x1.5 mm²) arrangement, so four 16 mm² conductors carry motor phases and protective earth, while two twisted pairs of 1.5 mm² wires supply brake and sensor circuits. With an outer diameter of 25.5 mm, the assembly fits standard cable glands used on modular machine frames. Copper conductor resistance is 1.21 Ohm/km at 20 °C; this low value limits voltage drop over long motor leads and keeps thermal rise modest during continuous current flow. The insulation system is rated for 600 V AC, matching the output of typical regenerative servo inverters, and the robust PUR jacket resists coolants, oils, and abrasion in moving-cable guides.
Electromagnetic and mechanical behaviour are further defined by a line-to-shield capacitance of 1.2 nF/m, a specification important for drive filters that limit leakage currents. Visual identification on busy cable trays is aided by the jacket tone RAL 2003, and flex performance is set by a minimum bend radius of 5 x D for fixed routing and 7.5 x D when the cable moves in energy chains. The conductor insulation can operate up to 90 °C in stationary installations and 80 °C under dynamic movement, so thermal derating is avoided in cabinets and gantries with moderate ambient levels.