RKL4405 Bosch Rexroth Indramat
Wake Industrial LLC is not an authorized distributor of this product.
MPN:
No Tariffs On US Orders- Straightforward Pricing: No Rush Fees, No Credit Card Fees
Current response time:
5 Minutes
3 Seconds
The Bosch Rexroth Indramat RKL4405 is part of the RKL Motor Power Cables series. This cable features a PUR jacket and a nominal diameter of 14.8 mm, as well as a construction of 4 x 2.5 mm² plus 2 x (2 x 1.0 mm²). It is halogen-free and rated for up to 5,000,000 bending cycles for drag chain use.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
The RKL4405 motor power cable is manufactured by Bosch Rexroth Indramat and belongs to the RKL Motor Power Cables series. This product is a multi-core electrical cable intended to route three-phase supply and auxiliary control lines from the inverter to the motor in automated machinery. Its flexible construction supports movement inside drag chains while maintaining stable power delivery for repeatable positioning and consistent machine cycles.
For stationary installation, the cable can be bent to a minimum radius of 5 x D, while dynamic applications require a radius of 7.5 x D. Endurance is rated for 5,000,000 flex cycles, which supports repeated motion in high-duty drag-chain service. The conductor resistance of 7.98 Ω/km helps limit voltage drop over longer cable runs, and the nominal outer diameter of 14.8 mm is useful when selecting clamps and cable glands. The cable also has a capacitance of 0.7 nF/m, which helps keep reactive current low in PWM drive systems. It is approved for use in drag chains, so repeated motion does not easily disturb the shielding or insulation during normal operation. These electrical and bending values support reliable routing where the cable must move with the axis through continuous machine travel.
The outer jacket is made from PUR, which provides good abrasion resistance and oil tolerance in industrial environments. The insulation system is halogen-free, helping reduce corrosive and toxic gas formation during a fire. Its conductor arrangement is 4x2.5 mm² + 2x(2x1.0 mm²), separating the main power conductors from the smaller auxiliary pairs inside the same cable body. This layout helps keep power transmission and auxiliary signals organized in confined carrier spaces. The combination of jacket material and conductor grouping suits automated equipment that operates with repetitive motion and moderate thermal loading.
Frequently Asked Questions about RKL4405:
Q: How many bending cycles can the Bosch Rexroth RKL4405 cable endure?
A: The RKL4405 power cable can withstand 5,000,000 bending cycles, making it suitable for applications with frequent movement.
Q: Is the RKL4405 cable suitable for use with drag chains?
A: Yes, the RKL4405 is designed for use in drag chains, allowing for flexible installation in dynamic environments.
Q: What is the minimum bend radius for fixed installations of the RKL4405 cable?
A: The minimum bend radius for fixed installation of the RKL4405 cable is 5 times its diameter.
Q: Is the jacket of the RKL4405 power cable halogen-free?
A: The RKL4405 features a halogen-free jacket, ensuring no halogen content for reduced toxic emissions during a fire.
Q: What is the conductor resistance of the RKL4405 cable at 20°C?
A: The conductor resistance of the RKL4405 at 20°C is 7.98 Ω/km, which ensures efficient power transmission over its length.