RKH0511 Bosch Rexroth Indramat
Wake Industrial LLC is not an authorized distributor of this product.
MPN:
No Tariffs On US Orders- Straightforward Pricing: No Rush Fees, No Credit Card Fees
Current response time:
6 Minutes
48 Seconds
The Bosch Rexroth Indramat RKH0511 is part of the RKH Hybrid Cables series and features RHS0005 and RHS0016 connectors. It supports up to 5 million bending cycles and operates in temperatures from -40 to 80 degrees Celsius. This cable has a dynamic bending radius of 10xD and a static bending radius of 5xD.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
The RKH0511 hybrid cable is produced by Bosch Rexroth Indramat within the RKH Hybrid Cables series. It combines power conductors and signal pairs inside one shielded jacket, allowing compact routing between drive controllers and field devices in automated cells. By merging two transmission paths, the cable reduces cabinet penetration points and simplifies drag-chain layouts while maintaining the electrical compatibility required by Rexroth motion systems.
The mechanical profile is defined for continuous motion duties. The cable is rated for 5,000,000 bending cycles, so repetitive flexing in energy chains will not jeopardize conductor integrity during the expected service life of a typical installation. Under movement the manufacturer prescribes a dynamic bending radius of 10xD; keeping the curve above this limit prevents insulation fatigue. When the assembly is fixed, the minimum static bend can be reduced to 5xD, supporting tight cabinet loops without stress cracking. Factory-installed terminals simplify commissioning, with connector 1 designated as RHS0005 and connector 2 specified as RHS0016, ensuring plug-and-play compatibility with matched Rexroth housings.
Thermal endurance complements the flex data. The cable remains functional from -40 °C up to 80 °C during operation, allowing the same harness to move beside motors, inside machines, or across chilled plant areas. Identical limits apply in storage, so installers do not need climate-controlled warehousing. Within this window the materials qualified by Bosch Rexroth Indramat for the RKH Hybrid Cables series keep dielectric strength stable and prevent signal drift. The vulcanized outer jacket, insulation system, and crimped contacts collectively maintain dielectric integrity and signal quality across the stated thermal window.
Frequently Asked Questions about RKH0511:
Q: What is the maximum number of bending cycles the RKH0511 cable can withstand?
A: The RKH0511 hybrid cable supports up to 5,000,000 bending cycles.
Q: Which connectors are used on the RKH0511 hybrid cable ends from Bosch Rexroth Indramat?
A: The RKH0511 features an RHS0005 connector on one end and an RHS0016 connector on the other.
Q: What is the specified dynamic bending radius for the RKH0511 cable?
A: The minimum dynamic bending radius for this cable is 10 times the cable diameter (10xD).
Q: What is the operating temperature range of the RKH0511 hybrid cable?
A: The operating temperature range for this cable is from -40 °C up to 80 °C.
Q: What is the static bending radius requirement for the Bosch Rexroth Indramat RKH0511 cable?
A: The static bending radius for the RKH0511 is 5 times its diameter (5xD).