RR51.1-7N-001-P-V1-FW Bosch Rexroth Indramat
MPN: R911200309
No Tariffs On US Orders- Straightforward Pricing: No Rush Fees, No Credit Card Fees
The Bosch Rexroth Indramat RR51.1-7N-001-P-V1-FW is part of the RD 500 Drive Controllers series and uses U/f curve control. This inverter DC drive features heat dissipation panel cooling for outputs up to 18.5 kW and operates with a voltage range of 530 to 670 V. It comes without a built-in brake chopper and supports 24 V external stand-by power.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
The RR51.1-7N-001-P-V1-FW is a drive controller power section produced by Bosch Rexroth Indramat for the RD 500 Drive Controllers series. It functions as a modular inverter stage that converts shared DC-bus energy into variable-frequency output for induction motors. This makes it suitable for conveyor, pump, and fan duties in automated lines where several loads may share a common power architecture. Because it is a power section rather than a standalone drive, it relies on the surrounding cabinet for the rectifier stage, control coordination, and other shared bus components.
This model operates from a DC inverter supply and accepts a bus voltage range of 530 to 670 V, allowing direct connection to the rectifier section of a multi-axis cabinet. Motor excitation uses U/f curve control, which keeps voltage proportional to frequency so the motor can maintain stable torque across the working speed range. Thermal management relies on a heat dissipation panel for drives up to 18.5 kW, and the panel transfers loss heat to a metal backplate without requiring forced air. The unit comes without a built-in brake chopper, so braking energy must be handled outside the power section when the application returns energy to the DC bus. That arrangement suits installations that use external braking hardware or allow regenerated energy to remain within the common bus system.
An external source supplies 24 V standby power, which keeps the control electronics active for communication and stored settings when the main link is de-energized. The unit is part of design generation 1, which gives it the first-generation mechanical format and connector arrangement used in the RD 500 platform. It is listed as firmware supplied separately, so the required software is provided apart from the power section rather than installed at the factory. This lets the same hardware platform be prepared for the intended control setup without changing the main inverter module.
Frequently Asked Questions about RR51.1-7N-001-P-V1-FW:
Q: Does the RR51.1-7N-001-P-V1-FW drive controller include a brake chopper?
A: The RR51.1-7N-001-P-V1-FW does not feature a built-in brake chopper.
Q: What type of control method is used in the RR51.1-7N-001-P-V1-FW?
A: This drive controller uses U/f curve control for motor operation.
Q: How is the RR51.1-7N-001-P-V1-FW cooled during operation?
A: Heat dissipation for this unit is managed via a panel for applications up to 18.5 kW.
Q: What voltage range does the RR51.1-7N-001-P-V1-FW support?
A: The supported input voltage range for this drive is 530 to 670 V.
Q: What power standby function does the RR51.1-7N-001-P-V1-FW provide?
A: This model offers a 24 V external standby power function for added flexibility in power management.