RD52.2-4B-003-L-A2-FW Bosch Rexroth Indramat
Wake Industrial LLC is not an authorized distributor of this product.
MPN: R911201244
The Bosch Rexroth Indramat RD52.2-4B-003-L-A2-FW is a drive controller from the RD 500 Drive Controllers series. It features field oriented vector control, a built-in brake chopper, and forced air cooling. The controller operates with a rated power of 3.0 kW and supports a voltage range of 380 to 480 V with an integrated mains filter.
Internal Product Review
The RD52.2-4B-003-L-A2-FW is a drive controller configured for converter 3 x AC supply. Field oriented vector control and a 380 to 480 V input range give the unit precise motor handling and dependable integration in industrial systems. A built-in brake chopper and integrated mains filter make this controller an excellent choice for efficient drive performance.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
The RD52.2-4B-003-L-A2-FW is manufactured by Bosch Rexroth Indramat and belongs to the RD 500 Drive Controllers series. This controller is installed between the three-phase mains and an industrial motor to modulate voltage and frequency so that speed, direction, and torque can be matched to machine demands. As a modular component, it integrates into cabinet racks that coordinate motion, positioning, and energy usage throughout automated assembly and material-handling equipment. This arrangement gives the drive a central role in applications that need adjustable motor performance instead of fixed-speed operation.
Input power is accepted through a three-phase AC converter front end that tolerates supply variations of 380 to 480 V, and the ±10% margin helps the unit remain functional when plant voltage fluctuates. Its nominal output is 3.0 kW, which is the continuous mechanical power the connected motor can deliver without derating. Closed-loop regulation is achieved with field-oriented vector control, which keeps motor current aligned for fast response during load changes and low-speed operation. Thermal stress is limited by forced-air cooling, where an internal fan moves air across heat sink fins to remove losses generated by the power semiconductors. This control method helps maintain stable torque production while the motor accelerates, runs at steady speed, or slows under command.
The unit is in design generation 2 and shares a common backplane and signal topology with other RD52 modules. For deceleration events, it contains a built-in brake chopper that diverts excess DC-link energy to an external resistor and helps prevent overvoltage trips during rapid stopping. Harmonic attenuation is aided by an integrated mains filter, so additional line components may not be needed in some installations. The standard function set includes external standby power and a starting lockout that blocks unintended motor runs after power is restored.