4.95 based on 202 reviews

🙶 We have never had a problem in the almost 20 years we have dealt with Wake. We would recommend them to any... 🙷

RD52.1-8N-110-L-V1-FW Bosch Rexroth Indramat

MPN: R911200784

No Tariffs On US Orders
  • Rated 4.5 (40 total ratings)
  • Straightforward Pricing: No Rush Fees, No Credit Card Fees
Ask for Availability

Preparing your secure checkout page...

The Bosch Rexroth Indramat RD52.1-8N-110-L-V1-FW is a drive controller from the RD 500 Drive Controllers series with a rated power of 110 kW and a voltage range of 700 V. This product uses forced air cooling, features field oriented vector control, and does not include a built-in brake chopper.

Quote Request Form:

Warranty
Wake Industrial Warranty

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The RD52.1-8N-110-L-V1-FW is a drive controller produced by Bosch Rexroth Indramat within the RD 500 Drive Controllers series. It regulates three-phase induction motors in automated machinery by converting DC-bus power into variable-frequency, variable-voltage output. This lets speed and torque follow programmed motion profiles in material-handling lines, process equipment, and other industrial systems that require controlled motor response. Because the controller adjusts both voltage and frequency, it can support smooth acceleration, controlled deceleration, and stable running under changing load conditions.

This model is sized for loads up to 110 kW, making it suitable for high-power duties such as pumps, compressors, and extruders. The DC link operates at a continuous 700 V, and the power input is an Inverter DC supply commonly used in systems with a shared rectifier. Motor performance is managed with field-oriented vector control, which supports accurate current regulation during speed changes and improves torque response at varying operating points. Internal heat is removed by forced air cooling, with airflow moving across the heat sink to carry away switching losses. The unit is supplied without a built-in brake chopper, so applications with frequent deceleration require an external braking resistor or a regenerative module.

For control integrity during power outages, a dedicated input provides 24 V standby power so encoder data and bus communications can remain active while the power stage is off. The unit is Design Generation 1, which identifies the first design generation used for this platform. Keeping the control section energized during a bus interruption helps the controller retain status handling and communication functions until the main drive power returns. This separation between control power and output-stage power is useful in coordinated systems where supervisory communication must remain available during a temporary supply loss.

Brake Chopper
Without built-in brake chopper
Control Type
Field oriented vector control
Cooling Type
Forced air cooling
Design Generation
1
Firmware Note
Firmware must be ordered as separate subposition
Functions
24 V stand-by power, external
Product Type
Drive Controller
Rated Power
110 kW
Supply Type
Inverter DC
Voltage Range
700 V
  • RD5218N110LV1FW
  • RD52 1 8N 110 L V1 FW
  • rd52.1-8n-110-l-v1-fw

Frequently Asked Questions about RD52.1-8N-110-L-V1-FW:

Q: What control type does the RD52.1-8N-110-L-V1-FW drive controller utilize?

A: The RD52.1-8N-110-L-V1-FW features field oriented vector control for its operation.

Q: What cooling method is provided for the RD52.1-8N-110-L-V1-FW drive controller?

A: This model uses forced air cooling to maintain optimal operating temperatures.

Q: What is the rated power output of the RD52.1-8N-110-L-V1-FW drive controller?

A: The RD52.1-8N-110-L-V1-FW delivers a rated power of 110 kW.

Q: Does the RD52.1-8N-110-L-V1-FW include a built-in brake chopper?

A: This drive controller is designed without a built-in brake chopper.

Q: What voltage range does the RD52.1-8N-110-L-V1-FW support?

A: The voltage range for this drive controller is 700 V, suitable for certain industrial applications.


Internal Product Review

  • ‘‘The RD52.1-8N-110-L-V1-FW is a Bosch Rexroth Indramat drive controller with field oriented vector control and a 110 kW rating. Forced air cooling and inverter DC supply support stable performance in demanding drive systems. The 700 V voltage range is a key advantage for high-power industrial applications.’’