The Bosch Rexroth Indramat RD52.1-8N-045-L-V1-FW is a drive controller from the RD 500 Drive Controllers series. It features a rated power of 45 kW, supports a voltage range of 700 V, and uses forced air cooling. This model has field oriented vector control and operates without a built-in brake chopper.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
Bosch Rexroth Indramat’s RD52.1-8N-045-L-V1-FW belongs to the RD 500 Drive Controllers series and is specified for variable-speed operation of three-phase motors in automated machinery. The unit functions as a drive controller that converts regulated DC energy into a commanded AC waveform. This allows motion axes to accelerate, hold a set speed, or decelerate under closed-loop control within process lines, packaging equipment, and material-handling cells.
The controller delivers a rated output of 45 kW, a power level suited for mid-range pumps, blowers, and conveyor drives. Its DC link accepts up to 700 V, allowing the inverter stage to synthesize high peak phase voltages while maintaining a compact bus capacitor. Regulation is handled by field-oriented vector control, which separates torque-producing and magnetizing currents so dynamic speed or position loops can be tuned with minimal steady-state error. Thermal energy is removed through forced air cooling; an internal fan drives cabinet air across the heat sink to keep semiconductor junction temperatures within limits and prevent derating at typical plant ambient conditions. For applications that dissipate kinetic energy, an external braking resistor can be added because the unit is supplied without a built-in brake chopper.
The DC bus is sourced from an inverter DC supply, so the controller is integrated downstream of a rectifier module rather than tied directly to the three-phase line. Control electronics remain powered during mains outages by an auxiliary feed that provides 24 V standby power, letting fieldbuses, encoders, and stored drive parameters remain active while the main converter is de-energized. Hardware details correspond to Design Generation 1, which matches first-generation RD 500 option cards. The operating software must be ordered as a separate subposition.
Frequently Asked Questions about RD52.1-8N-045-L-V1-FW:
Q: What is the rated power output of the RD52.1-8N-045-L-V1-FW drive controller?
A: The RD52.1-8N-045-L-V1-FW operates with a rated power of 45 kW.
Q: What type of cooling does the RD52.1-8N-045-L-V1-FW controller use?
A: This controller uses forced air cooling for thermal management during operation.
Q: What motor control method is used by the RD52.1-8N-045-L-V1-FW?
A: The RD52.1-8N-045-L-V1-FW functions with field oriented vector control for precise motor management.
Q: What input voltage range and supply type does the RD52.1-8N-045-L-V1-FW require?
A: It is designed to work within a voltage range of 700 V supplied via inverter DC.
Q: Does the RD52.1-8N-045-L-V1-FW have an integrated brake chopper?
A: This model does not include a built-in brake chopper.